Section 6 (P-HEV Hybrid Powertrain Control System (Diagnostics) (1 Of 2))
WARNING: This page is about a different variant/trim than selected.
- Basic Diagnostic Procedure
- Check List for Interview
- General Description
- Electrical Component Location
- Control Module I/O Signal
- Inspection Mode
- Procedure
- Notes
- Inspection Mode 1
- Inspection Mode 2
- Inspection Mode 3
- Inspection Mode 4
- Inspection Mode 5
- Inspection Mode 6
- Inspection Mode 7
- Inspection Mode 8
- Inspection Mode 9
- Inspection Mode 10
- Inspection Mode 11
- Inspection Mode 12
- Inspection Mode 13
- Inspection Mode 14
- Inspection Mode 15
- Inspection Mode 16
- Inspection Mode 17
- Inspection Mode 18
- Inspection Mode 19
- Inspection Mode 20
- Inspection Mode 21
- Inspection Mode 22
- Inspection Mode 23
- Inspection Mode 24
- Inspection Mode 25
- Inspection Mode 26
- Inspection Mode 27
- Inspection Mode 28
- Inspection Mode 29
- Inspection Mode 30
- Inspection Mode 31
- Inspection Mode 32
- Inspection Mode 33
- Inspection Mode 34
- Inspection Mode 35
- Inspection Mode 36
- Inspection Mode 37
- Inspection Mode 38
- Inspection Mode 39
- Inspection Mode 40
- Inspection Mode 41
- Inspection Mode 42
- Inspection Mode 43
- Inspection Mode 44
- Inspection Mode 45
- Inspection Mode 46
- Inspection Mode 47
- Inspection Mode 48
- Inspection Mode 49
- Procedure
- Diagnosis System
- Warning Light Illumination Pattern
- Diagnostic Procedure for Subaru Select Monitor Communication
- Data Monitor
- Freeze Frame Data
- Active Test
- Work Support
- All Readiness Diagnostic Code(s)
- Diagnostic Trouble Code (DTC)
- Diagnostic Procedure with Diagnostic Trouble Code (DTC)
- DTC P0560-14: System Voltage (Batt) Circuit Short To Ground Or Open
- DTC P058A-01: Auxiliary Battery Monitor Module General Electrical Failure
- DTC P0606-47: Hybrid/EV Powertrain Control Module Processor Watchdog/Safety MCU Failure
- DTC P0606-87: Hybrid/EV Powertrain Control Module Processor To Monitoring Processor Missing Message
- DTC P0606-94: Hybrid/EV Powertrain Control Module Processor Unexpected Operation
- DTC P060A-29: Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid
- DTC P060A-44: Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure
- DTC P060A-45: Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure
- DTC P060A-47: Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog/Safety MCU Failure
- DTC P060A-49: Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure
- DTC P060A-87: Hybrid/EV Powertrain Control Module Processor From Monitoring Processor Missing Message
- DTC P060A-94: Hybrid/EV Powertrain Control Module Monitoring Processor Unexpected Operation
- DTC P060B-1C: Hybrid/EV Powertrain Control Module A/D Processing Voltage Out Of Range
- DTC P060B-49: Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure
- DTC P060B-71: Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck
- DTC P062F-44: Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure
- DTC P0688-1F: ECM/Pcm Power Relay Sense Circuit Intermittent
- DTC P0705-62: Transmission Range Sensor "A" Circuit (PRNDL Input) Signal Compare Failure
- DTC P0A0A-13: High Voltage System Interlock Circuit Open
- DTC P0A0A-92: High Voltage System Interlock Performance Or Incorrect Operation
- DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure
- DTC P0A1B-94: Drive Motor "A" Control Module Unexpected Operation
- DTC P0A1F-94: Hybrid/EV Battery Energy Control Module Unexpected Operation
- DTC P0A2A-11: Drive Motor "A" Temperature Sensor Circuit Short To Ground
- DTC P0A2A-15: Drive Motor "A" Temperature Sensor Circuit Short To Auxiliary Battery Or Open
- DTC P0A2A-1C: Drive Motor "A" Temperature Sensor Voltage Out Of Range
- DTC P0A2A-1F: Drive Motor "A" Temperature Sensor Circuit Intermittent
- DTC P0A36-11: Generator Temperature Sensor Circuit Short To Ground
- DTC P0A36-15: Generator Temperature Sensor Circuit Short To Auxiliary Battery Or Open
- DTC P0A36-1C: Generator Temperature Sensor Voltage Out Of Range
- DTC P0A36-1F: Generator Temperature Sensor Circuit Intermittent
- DTC P0A93-00: Inverter "A" Cooling System Performance
- DTC P0AA0-00: Hybrid/EV Battery Positive Contactor Circuit Stuck Closed
- DTC P0AA0-73: Hybrid/EV Battery Positive And Negative Contactor Actuator Stuck Closed
- DTC P0AA3-73: Hybrid/EV Battery Negative Contactor Actuator Stuck Closed
- DTC P0AA6-49: Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure
- DTC P0AA7-49: Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure
- DTC P0ABF-00: Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance
- DTC P0AD9-11: Hybrid/EV Battery Positive Contactor Circuit Short To Ground
- DTC P0AD9-15: Hybrid/EV Battery Positive Contactor Circuit Short To Auxiliary Battery Or Open
- DTC P0ADD-11: Hybrid/EV Battery Negative Contactor Circuit Short To Ground
- DTC P0ADD-15: Hybrid/EV Battery Negative Contactor Circuit Short To Auxiliary Battery Or Open
- DTC P0AE1-73: Hybrid/EV Battery PRECHARGE Contactor Actuator Stuck Closed
- DTC P0AE4-11: Hybrid/EV Battery PRECHARGE Contactor Circuit Short To Ground
- DTC P0AE4-15: Hybrid/EV Battery PRECHARGE Contactor Circuit Short To Auxiliary Battery Or Open
- DTC P0B23-1C: Hybrid/EV Battery "A" Voltage Sensor Voltage Out Of Range
- DTC P0C73-96: Motor Electronics Coolant Pump "A" Component Internal Failure
- DTC P0C76-00: Hybrid/EV Battery System Discharge Time Too Long
- DTC P0D07-00: Hybrid/EV Battery Charging System Positive Contactor Stuck Closed
- DTC P0D07-73: Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed
- DTC P0D0E-73: Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed