LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2020 >> Crosstrek Base, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 6 (P-HEV Hybrid Powertrain Control System (Diagnostics) (1 Of 2)) >> Data Monitor >> List

Data Monitor: List

WARNING: This page is about a different variant/trim than selected.
Item Contents Display range Standard Note
Vehicle Speed Vehicle speed Min.: 0 km/h (0 MPH), Max.: 255 km/h (158 MPH) Vehicle stopped: 0 km/h (0 MPH)
While driving at a constant speed: No significant fluctuation
-
Vehicle Speed when DC Quick Charging Connector Connect Vehicle speed when connected to plug-in charger inlet Min.: 0 km/h (0 MPH), Max.: 327.67 km/h (203.61 MPH) - -
Engine Speed Engine speed Min.: 0.00 rpm, Max.: 16383.75 rpm Engine stopped: 0 rpm
While engine running at a constant speed: No significant fluctuation
-
Calculate Load Calculate load Min.: 0.0%, Max.: 100.0% - Value increases in proportion to increase in load
  • Throttle valve status
  • Air cleaner condition
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Cold start → Fully warmed up: Gradually rises
After warming up: 75 to 100°C (167 to 212°F)
-
Starter Switch Signal Starter ON/OFF signal ON or OFF Starter ON: ON -
Engine Start Request (Hybrid Battery Charging) Engine idling request to charge HV battery ON or OFF Requesting HV battery charging: ON
  • Battery ECU assembly
  • HV battery
Engine Run Time Elapsed time after starting engine Min.: 0 sec, Max.: 65535 sec Elapsed time after starting engine Elapsed time from initial engine start until the power switch is turned off.
Accelerator Position Accelerator pedal depressed angle Min.: 0.0%, Max.: 127.5% Accelerator pedal fully depressed: 100%
Accelerator pedal released: 0%
Accelerator pedal sensor assembly
Accelerator Pedal Status Accelerator Pedal Status ON or OFF Accelerator pedal depressed: ON
Accelerator pedal released: OFF
Accelerator pedal sensor assembly
Accelerator Position Sensor No. 1 Voltage % Accelerator pedal position sensor No. 1 Min.: 0.00%, Max.: 100.00% Accelerator pedal depressed: Changes with accelerator pedal position Sensor voltage is multiplied by 20 and displayed as a percentage
Accelerator Position Sensor No. 2 Voltage % Accelerator pedal position sensor No. 2 Min.: 0.00%, Max.: 100.00% Accelerator pedal depressed: Changes with accelerator pedal position Sensor voltage is multiplied by 20 and displayed as a percentage
Throttle Position Sensor No. 1 Voltage % Throttle position sensor Min.: 0.0%, Max.: 100.0% - Throttle valve status
Master Cylinder Control Torque Braking torque equivalent to master cylinder brake fluid pressure (Total braking torque) Min.: -4096 Nm, Max.: 4095.87 Nm Brake pedal depressed: Changes with the brake pedal pressure Master cylinder brake fluid pressure control torque = hydraulic brake control torque + regenerative brake torque Master cylinder pressure sensor
Shift Position Current shift state P/R/N/D/B Matches currently selected shift state: P, R, N, D or B Shift state When the value of Shift Position (Meter) is "Not Displayed" and the value of Shift Position is "N", the actual shift position cannot be determined and the parking lock may be engaged.
Shift Position (Meter) Shift position of meter display Not Displayed/P/R/N/D/B Matches currently selected shift state: P, R, N, D or B Shift state
Transaxle Oil Temperature Hybrid vehicle transaxle oil temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)
While driving: Varies depending on vehicle operating conditions
-
Transaxle Oil Temperature Sensor Voltage Hybrid vehicle transaxle oil temperature sensor voltage Min: 0.00 V, Max: 4.99 V - -
FR Wheel Speed Front wheel speed RH Min.: 0 km/h (0 MPH), Max.: 327.67 km/h (204 MPH) Vehicle stopped: 0 km/h (0 MPH)
Vehicle being driven at a constant speed: No large fluctuations in displayed speed
-
FL Wheel Speed Front wheel speed LH Min.: 0 km/h (0 MPH), Max.: 327.67 km/h (204 MPH) Vehicle stopped: 0 km/h (0 MPH)
Vehicle being driven at a constant speed: No large fluctuations in displayed speed
-
RR Wheel Speed Rear wheel speed RH Min.: 0 km/h (0 MPH), Max.: 327.67 km/h (204 MPH) Vehicle stopped: 0 km/h (0 MPH)
Vehicle being driven at a constant speed: No large fluctuations in displayed speed
-
RL Wheel Speed Rear wheel speed LH Min.: 0 km/h (0 MPH), Max.: 327.67 km/h (204 MPH) Vehicle stopped: 0 km/h (0 MPH)
Vehicle being driven at a constant speed: No large fluctuations in displayed speed
-
Atmospheric Pressure Atmospheric pressure Min.: 0 kPa (0 psi), Max.: 255 kPa (37 psi) Constant: Atmosphere pressure -
Intake Manifold Absolute Pressure Intake manifold pressure of engine Min.: 0 kPa (0 psi), Max.: 2047.96 kPa (297 psi) Power switch on (IG) or engine stopped: Atmosphere pressure Values less than atmospheric pressure are indicated while the engine is running
Ambient Temperature Ambient air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Power switch on (IG): Same as ambient air temperature Ambient temperature sensor
Intake Air Temperature Engine intake air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Constant: Almost same as ambient air temperature -
BATT Voltage Battery (12V) voltage (Battery ECU assembly power source voltage) Min.: 0.00 V, Max.: 16.00 V 11.00 to 15.00 V BATT terminal
Smoothed Value of BATT Voltage Smoothed value of Battery (12V) voltage Min.: 0.00 V, Max.: 16.00 V 11.000 to 15.000 V Hybrid vehicle control ECU assembly
Warmup Cycle Cleared DTC The number of times the engine is warmed up after clearing DTCs Min.: 0, Max.: 255 MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine: Increases once -
Distance from DTC Cleared Drive distance after clearing DTCs Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) - -
Time after DTC Cleared Elapsed time after clearing DTCs Min.: 0 min, Max.: 65535 min - Time elapsed after DTCs are cleared (Not counted when the power switch is off).
MIL MIL status ON or OFF - -
Running Time from MIL ON Running time from MIL on Min.: 0 min, Max.: 65535 min - -
Total Distance Traveled Drive total distance Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) - -
Total Distance Traveled - Unit Drive total distance unit km or mile - -
MIL ON Run Distance Drive distance from MIL on Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) - -
Number of Emission DTC Emissions-related DTCs Min.: 0, Max.: 127 - -
OBD Requirements OBD Requirements - - -
IGB Signal Status IGB signal status ON or OFF Power switch on (IG) or during charging: ON IGB terminal
IGB Keeping Status IGB Keeping Status ON or OFF Power switch on (IG) or during charging: ON IGB terminal
IG2 Signal Status IG2 signal status ON or OFF Power switch on (IG) or on (READY): ON IG2 terminal
+B3M Signal Status +B3M Signal Status ON or OFF IGCT relay Operating: ON +B3M terminal
MRL2 Signal Status MRL2 Signal Status ON or OFF IGCT relay Operating: ON MRL2 terminal
Ready Signal Ready signal status ON or OFF Power switch on (READY): ON -
HV Activate Condition Hybrid vehicle control system power source mode status Normal/Remote Air Control System/Remote Hybrid Vehicle Control System started using power switch: Normal
Hybrid vehicle control system started using remote air control system function: Remote Air Control System Hybrid vehicle control system started using remote starter: Remote
-
MG Activate Condition Motor generator control system status ON or OFF Power switch on (IG) or on (READY): ON -
DSS Control Status Control status of DSS (Driving Support System) Not Control/Available/Unavailable/Disable - -
Generate Torque (Request from DSS) Generated drive torque requested from DSS (Driving Support System) Min.: -4096.00 Nm, Max.: 4095.87 Nm - -
Primary Driving Force Adjustment Result Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation Accelerator/DSS Drive force requested by Accelerator pedal operation selected: Accelerator Drive force requested by DSS selected: DSS -
SMRG Status Operating state of SMRG (primary circuit monitor) ON or OFF Power switch on (READY): ON
  • HV battery junction block assembly
  • Wire harness
SMRG Control Status Commanded state of SMRG ON or OFF Power switch on (READY): ON
  • HV battery junction block assembly
  • Wire harness
SMRB Status Operating state of SMRB (primary circuit monitor) ON or OFF Power switch on (READY): ON
  • HV battery junction block assembly
  • Wire harness
SMRB Control Status Commanded state of SMRB ON or OFF Power switch on (READY): ON
  • HV battery junction block assembly
  • Wire harness
SMRP Status Operating state of SMRP (primary circuit monitor) ON or OFF Immediately after the power switch on (ST-ON) state occurred: ON
After the above timing: OFF
Cannot be confirmed using the SUBARU SELECT MONITOR.
Use an oscilloscope.
  • HV battery junction block assembly
  • Wire harness
SMRP Control Status Commanded state of SMRP ON or OFF Immediately after the power switch on (ST-ON) state occurred: ON
After the above timing: OFF
Cannot be confirmed using the SUBARU SELECT MONITOR.
Use an oscilloscope.
  • HV battery junction block assembly
  • Wire harness
WIN Control Limit Power WIN control limit power Min.: -327.68 kW, Max.: 327.67 kW -27.4 kW -
WOUT Control Limit Power WOUT control limit power Min.: -327.68 kW, Max.: 327.67 kW HV mode: 24 kW or less
EV mode: 65.4 kW or less
-
Charging Permission Signal by Main CPU Charging permission signal by main CPU NG or OK - -
Charging Permission Signal by Sub CPU Charging permission signal by sub CPU NG or OK - -
Charging Permission Answerback Signal from Plug-in Control ECM Charging permission answerback signal from plug-in control ECM NG or OK - -
A/C Consumption Power A/C consumption power Min.: 0.00 kW, Max.: 12.75 kW While the air conditioning system is operating: 0 to 5.00 kW Air conditioning system
A/C Usable Power A/C usable power Min.: 0.00 kW, Max.: 12.75 kW - -
HV/EV Mode Switch Hybrid mode switch condition ON or OFF Hybrid mode switch not operated: OFF
Hybrid mode switch being pushed and held: ON
Hybrid mode switch Circuit
EV Mode Status EV mode status Normal/EV Mode/Changing to HV Mode from EV Mode/Changing to EV Mode from HV Mode/EV CITY Mode/Changing to HV Mode from EV CITY Mode/Battery Charge Mode/Changing to HV Mode from Battery Charge Mode/Standby for Battery Charge Mode/EV AUTO Mode/Changing to HV Mode from EV AUTO Mode - -
Drive Mode Hybrid vehicle control ECU assembly recognized drive mode None/EV Mode/HV Mode by Switch/HV Mode - -
Hybrid Control System Control Mode Hybrid vehicle control ECU assembly controlled vehicle mode None/Driving Mode/External Power Supply Mode/Charging/Discharging Mode/Other - -
Inter Lock Switch Interlock switch condition ON or OFF Power switch on (IG), service plug grip not installed: ON ILK terminal
Inter Lock Switch (MG) Interlock switch condition ON or OFF Power switch on (IG), inverter cover not installed: ON Inverter with converter assembly
Back Up Light Relay Back up light switch condition ON or OFF Shift lever in R: ON -
VSC/TRC OFF Switch VSC condition OFF/TRC OFF Mode/TRC/VSC OFF Mode - -
Airbag Status (Collision) Airbag sensor assembly collision detection ON or OFF Collision detection by the airbag sensor assembly: ON -
Airbag Status (Collision) (CAN) Airbag sensor assembly collision detection (CAN) Normal/Collision from Back/Airbag Circuit Abnormal/Safing/Collision from Front or Side - -
Airbag Status (Normal) Control state of airbag sensor assembly ON or OFF When the airbag sensor assembly is operating normally: ON -
Crank Position Crankshaft position Min.: -128 deg (CA), Max.: 127 deg (CA) - -
Remote Air Control System Remote air conditioning system operability Unable or Able - -
AC Charging Plug-in charging operability Unable or Able - -
Elapsed time from HV ECM Boot Up Hybrid vehicle control ECU assembly started Min.: 0 sec, Max.: 65535 sec - -
IG OFF Elapsed Time Cumulative time since power switch turned off (from ECM) Min.: 0 min, Max.: 655350 min - -
Generator Revolution Generator speed (detected by resolver sensor) Min.: -32768 rpm, Max.: 32767 rpm During charge or discharge: Varies depending on vehicle operating conditions Generator speed is set to obtain requested target engine speed
  • Transmission assembly
  • Inverter with converter assembly
Target Generator Torque Generator torque request value Min.: -4096.00 Nm, Max.: 4095.87 Nm During charge or discharge: Varies depending on vehicle operating conditions Generator speed is set to obtain requested target engine speed
  • Transmission assembly
  • Inverter with converter assembly
Generator Torque Generator torque execution value Min.: -4096.00 Nm, Max.: 4095.87 Nm One second after engine automatically starts with shift lever in P (Condition before engine start: Power switch on (READY), engine stopped, A/C fan speed high and headlights on): Within +/- 20% of target Generator torque
  • Hybrid vehicle control ECU assembly
  • Transmission assembly
  • Inverter with converter assembly
Motor Revolution Motor speed (detected by resolver sensor) Min.: -32768 rpm, Max.: 32767 rpm While driving: Varies depending on vehicle speed Motor speed changes in proportion to vehicle speed.
Motor speed is not influenced by accelerator pedal opening angle, engine speed or Generator speed.
  • Transmission assembly
  • Inverter with converter assembly
Target Motor Torque Motor torque request value Min.: -4096.00 Nm, Max.: 4095.87 Nm While driving: Varies depending on vehicle operating conditions
  • Hybrid vehicle control ECU assembly
  • Transmission assembly
  • Inverter with converter assembly
Motor Torque Motor torque execution value Min.: -4096.00 Nm, Max.: 4095.87 Nm After full-load acceleration with power switch on (READY) and engine stopped: Within +/- 20% of target Motor torque
  • Hybrid vehicle control ECU assembly
  • Inverter with converter assembly
  • Transmission assembly
Request Motor Regenerative Brake Torque Requested Motor regenerative braking torque Min.: -4096.00 Nm, Max.: 4095.87 Nm While braking: Varies depending on vehicle operation conditions When regenerative braking is being performed, current flows from the Motor to charge the HV battery and braking torque is generated. Electronically controlled brake system
Motor Regenerate Brake Execution Torque Motor regenerative braking execution torque Min.: -4096.00 Nm, Max.: 4095.87 Nm While braking: Varies depending on vehicle operation conditions
  • Hybrid vehicle control ECU assembly
  • Transmission assembly
  • Inverter with converter assembly
Generator Temperature Generator temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F)
While driving: Varies depending on vehicle operating conditions
-
Generator Temperature Sensor Voltage Generator temperature sensor voltage Min.: 0 V, Max.: 4.99 V - -
Generator Temperature just after IG ON Generator temperature soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Generator Maximum Temperature Maximum Generator temperature after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Motor Temperature Motor temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F)
While driving: Varies depending on vehicle operating conditions
-
Motor Temperature Sensor Voltage Motor temperature sensor voltage Min.: 0 V, Max.: 4.99 V - -
Motor Temperature just after IG ON Motor temperature soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Motor Maximum Temperature Maximum Motor temperature after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Generator Inverter Calculated Temperature Generator inverter temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F)
While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)
Inverter with converter assembly
Generator Inverter Calculated Temperature just after IG ON Generator inverter temperature soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Generator Inverter Calculated Maximum Temperature Maximum generator inverter temperature after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Motor Inverter Temperature Motor inverter temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F)
While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)
Inverter with converter assembly
Motor Inverter Temperature just after IG ON Motor inverter temperature soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Motor Inverter Maximum Temperature Maximum motor inverter temperature after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Boosting Converter Temperature (Upper) Boost converter temperature (upper) Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F)
While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)
Inverter with converter assembly
Boosting Converter Temperature (Lower) Boost converter temperature (lower) Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F)
While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)
Inverter with converter assembly
Boosting Converter Temperature just after IG ON Boost converter temperature soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Boosting Converter Maximum Temperature Maximum converter temperature after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Generator Inverter Operation Request Generator inverter operation request Shutdown/Phase ON/Discharge/Insulation Resistance Measurement/Output Torque/Emergency Shutdown/Shutdown during Insulation Resistance Measurement - -
Generator Inverter Fail Generator inverter stopped ON or OFF Generator inverter stopped: ON
Normal: OFF
-
Generator Inverter Shutdown Status Generator inverter shutdown status Awake or Shutdown Generator inverter shutdown: Shutdown
Normal: Awake
-
Motor Inverter Operation Request Motor inverter operation request Shutdown/Phase ON/Discharge/Insulation Resistance Measurement/Output Torque/Emergency Shutdown/Shutdown during Insulation Resistance Measurement - -
Motor Inverter Fail Motor inverter stopped ON or OFF Motor inverter stopped: ON
Normal: OFF
-
Motor Inverter Shutdown Status Motor inverter shutdown status Awake or Shutdown Motor inverter shutdown: Shutdown
Normal: Awake
-
Boosting Converter Operation Request Boost converter operation request Normal/Boosting Stop/Upper Arm ON/Maximum Boosting/Output Torque/Upper Arm Lowering - -
Boosting Converter Fail Boost converter stopped ON or OFF Boost converter stopped: ON
Normal: OFF
-
Boosting Converter Shutdown Status Boost converter shutdown status Awake or Shutdown Boost converter shutdown: Shutdown
Normal: Awake
-
Generator Carrier Frequency Generator Carrier Frequency 0.75 kHz/1.25 kHz/2.5 kHz/3.75 kHz/5 kHz/10 kHz/Electrical Power Loss Reduction Mode - -
Generator Control Mode Generator control mode Sine Wave/Overmodulation/Square Wave/Electrical Power Loss Reduction Mode PWM: Sine Wave
Variable PWM: Overmodulation
Rectangular wave: Square Wave
-
Motor Carrier Frequency Motor carrier frequency 0.75 kHz/1.25 kHz/2.5 kHz/3.75 kHz/5 kHz/10 kHz/Electrical Power Loss Reduction Mode - -
Motor Control Mode Motor control mode Sine Wave/Overmodulation/Square Wave/Electrical Power Loss Reduction Mode PWM: Sine Wave
Variable PWM: Overmodulation
Rectangular wave: Square Wave
-
Boosting Converter Carrier Frequency Boost converter signal carrier frequency 9.55 kHz/9.13 kHz/8.71 kHz/8.29 kHz/7.87 kHz/7.45 kHz/4.8 kHz - -
VL-Voltage before Boosting High voltage before it is boosted Min.: 0.0 V, Max.: 32767.5 V Power switch on (READY): Practically the same as the HV battery voltage
  • HV battery
  • Inverter with converter assembly
VH-Voltage after Boosting High voltage after it is boosted Min.: 0.0 V, Max.: 32767.5 V Engine revving up with shift lever in P: After boosted voltage to below approximately 650 V Inverter with converter assembly
Boost Ratio Boost converter boost ratio Min.: 0.0%, Max.: 100.0% - Inverter with converter assembly
V Phase Generator Current V phase generator current Min.: -3276.8 A, Max.: 3276.7 A - -
W Phase Generator Current W phase generator current Min.: -3276.8 A, Max.: 3276.7 A - -
V Phase Motor Current V phase motor current Min.: -3276.8 A, Max.: 3276.7 A - -
W Phase Motor Current W phase motor current Min.: -3276.8 A, Max.: 3276.7 A - -
DC/DC Converter Operation Status DC/DC converter operating state During Stop Request to MG ECU by HV ECM/Stop/Normal Operation - -
DC/DC Converter Drive Request DC/DC converter operation request Stop Request/Drive Request/Abnormal Detection Signal Check Request - -
Target DC/DC Converter Voltage DC/DC converter target step-down voltage Min.: 0.0 V, Max.: 25.5 V - -
Inverter Coolant Water Temperature Inverter coolant temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Cold start → Fully warmed up: Gradually rises
System operating normally: Controlled at 65°C (149°F) or less
  • Inverter with converter assembly
  • Inverter water pump assembly
  • Cooling fan system
  • Inverter cooling system
Inverter Water Pump Duty Ratio Inverter water pump motor driver request duty Min.: 0.0%, Max.: 399.9% Power switch on (READY): 62.50 to 93.75% Hybrid vehicle control ECU assembly
Inverter Water Pump Revolution Inverter water pump assembly speed Min.: 0 rpm, Max.: 65535 rpm Power switch on (READY): 1000 to 9300 rpm When the inverter water pump assembly is not operating: Lower than 200 rpm
Overvoltage Input to Inverter Overvoltage detection into inverter ON or OFF Overvoltage is detected into inverter: ON
Normal: OFF
-
Inverter Emergency Shutdown (Main CPU) Inverter emergency shutdown ON or OFF Inverter emergency shutdown: ON
Normal: OFF
-
Inverter Emergency Shutdown (Sub CPU) Inverter emergency shutdown ON or OFF Inverter emergency shutdown: Normal: OFF -
Overvoltage Input to Boosting Converter Overvoltage detection into boost converter ON or OFF Overvoltage is detected into boost converter: ON
Normal: OFF
-
Hybrid Battery SOC HV battery state of charge Primary calculated from charging and discharging amperage Min.: 0.0%, Max.: 100.0% Constant: 0.0 to 100.0%
  • HV battery
  • Battery ECU assembly
  • Hybrid vehicle control ECU assembly
Hybrid Battery SOC of Immediately after IG ON HV battery state of charge soon after power switch on (IG) Min.: 0.0%, Max.: 127.5% - -
Hybrid Battery Maximum SOC Maximum SOC after power switch turned on (IG) in current trip Min.: 0.0%, Max.: 127.5% - -
Hybrid Battery Minimum SOC Minimum SOC after power switch turned on (IG) in current trip Min.: 0.0%, Max.: 127.5% - -
Hybrid Battery Voltage HV battery voltage Min.: 0.00 V, Max.: 1023.98 V Power switch on (READY): 285 to 380 V
  • HV battery
  • Battery ECU assembly
  • Hybrid vehicle control ECU assembly
Hybrid Battery Current HV battery current Min.: -327.68 A, Max.: 327.67 A Power switch on (IG): -4 to 4 A
  • HV battery
  • Power cable
  • Inverter with converter assembly
  • Battery current sensor
Hybrid Battery Current for Driving Control Hybrid battery current for driving control Min.: -327.68 A, Max.: 327.67 A -
  • Discharging amperage is indicated by a positive value
  • Charging amperage is indicated by a negative value
Hybrid Battery Charging Power HV battery charging power Min.: -327.68 kW, Max.: 327.67 kW - -
Hybrid Battery Control Status on Thermal Keeping and Charging HV battery heating/charging state Unoperated/Charging/Thermal Keeping/Thermal Keeping and Charging - -
Charging Voltage for Hybrid Battery HV battery charging voltage (VCHG sensor value) Min.: 0.0 V, Max.: 6553.5 V - -
Hybrid Battery Charging and Discharging Permission Status with Hybrid Battery Thermal Keep HV battery charge/discharge state during temperature adjustment NG/Charging NG and Discharging OK/Charging OK and Discharging NG/OK - -
Hybrid Battery Temperature when Charging Start HV battery temperature when charging start Min.: -32768°C (-58950°F), Max.: 32767°C (59012°F) - -
Hybrid Battery Maximum Temperature HV battery highest temperature during current trip Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F) - -
Hybrid Battery Minimum Temperature HV battery lowest temperature during current trip Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F) - -
Hybrid Battery Cooling Fan Low Speed Request Battery cooling blower assembly Lo speed requested ON or OFF Constant: ON or OFF -
Hybrid Battery Cooling Necessity before Charging HV battery cooling necessary before charging ON or OFF - -
History of Hybrid Battery Cooling Cancel HV battery cooling suspended None or Done - -
Short Wave Highest Value Level Waveform voltage level in abnormal insulation detection circuit in Battery ECU assembly Not Judge/Normal/Insulation Lower LV2/Insulation Lower LV3 Judgment not completed: Not Judge
Normal: Normal condition
Medium low level: Insulation Lower LV2
Severe low level: Insulation Lower LV3
High voltage circuit
Insulation Resistance Division Check Completion using MG Inv Insulation Resistance Division Check Completion using MG inv Not Complete/Complete Decreased insulation resistance judgment for motor and generator inverter has completed: Complete After turning the power switch from on (READY) to off, compare the value of Data List item "Short Wave Highest Value Level" before and after the motor and generator inverter are shut down.
Insulation Resistance Division Check Completion using A/C Inv Insulation resistance division check completion using A/C inv Not Complete/Complete Decreased insulation resistance judgment for the air conditioning inverter has completed: Complete Check the value of Data List item "Short Wave Highest Value Level" before and after the air conditioning inverter is shut down.
Insulation Resistance Division Check Completion using SMR Insulation resistance division check completion using SMR Not Complete/Complete Decreased insulation resistance judgment for the system main relays has completed: Complete Check the value of Data List item "Short Wave Highest Value Level" before and after the system main relays are turned off.
Insulation Resistance Division Check Completion using AC Charging Area Insulation resistance division check completion using AC charging area Not Complete/Complete Decreased insulation resistance judgment for the AC charging relays has Complete Check the value of Data List item "Short Wave Highest Value Level" before and after the AC charging relays are turned off.
Short Wave Highest Value Availability just after MG Inv On/Off Short wave highest value availability just after MG inv on/off Yes or No The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after the motor and generator inverter are turned on/off: No -
Short Wave Highest Value Availability just after A/C Inv On/Off Short wave highest value availability just after A/C inv on/off Yes or No The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after air conditioning inverter turned on/off. No -
Short Wave Highest Value Availability just after SMR On/Off Short wave highest value availability just after SMR on/off Yes or No The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after system main relays turned on/off. No -
Short Wave Highest Value Availability just after AC Charging Relay On/Off Short wave highest value availability just after AC charging relay on/off Yes or No The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after AC charging relays turned on/off. No -
Permit Start by Immobilizer Status of starting permission by immobilizer (immobilizer to Hybrid vehicle control ECU assembly) No Judgment/OK/NG - -
Auxiliary Battery Voltage Battery (12V) voltage Min.: 0.00 V, Max.: 16.00 V Always: 11.00 to 15.00 V When power switch on (READY): approx. 12.5 to 15.0 V.
When power switch on (IG): same as Battery (12V) voltage (approx. 12 V). If the voltage becomes 11 V or less when the power switch is on (READY), the Hybrid vehicle control ECU assembly stores Inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the power switch will not be able to be turned on (READY).
  • Battery (12V)
  • Hybrid vehicle converter
Auxiliary Battery Current Battery (12V) current Min.: -125.00 A, Max.: 124.99 A - -
Smoothed Value of Auxiliary Battery Temperature Smoothed value of Battery (12V) temperature Min.: -40.0°C (-40.0°F), Max.: 6513.5°C (11756.3°F) - -
Auxiliary Battery Voltage Low Times Battery (12V) voltage low times Min.: 0, Max.: 255 - -
Auxiliary Battery Voltage at Low Voltage Checking Initiation Voltage of Battery (12V) voltage low judgment Min.: 0.00 V, Max.: 20.00 V - -
Auxiliary Battery Voltage Low Status by Hybrid Control ECM Battery (12V) voltage drop ON or OFF - -
Auxiliary Battery Voltage Low Status from Hybrid Battery Control ECM Existence of Battery (12V) voltage drop signal (from battery ECM) ON or OFF - -
Auxiliary Battery Voltage Low Status from Plug-in Control ECM Existence of Battery (12V) voltage drop signal (from Electric vehicle charger assembly) ON or OFF - -
Auxiliary Battery Supply Power during AC Charging Estimated power supplied to Battery (12V) during plugin charging Min.: -327.68 kW, Max.: 327.67 kW - -
Target Charging Power Electric vehicle charger assembly requested power for charging Min.: -327.68 kW, Max.: 327.67 kW - -
Charging Status Hybrid vehicle control ECU assembly recognized charging state Stop/Preparing/Charging/Process to Stop - -
Elapsed Time after Charging Status Transition Time elapsed since charging started Min.: 0 ms, Max.: 655350 ms - -
Number of Charging (Same System Voltage) Number of charging operations performed using same power supply voltage (above a certain number of times) Min.: 0, Max.: 255 - -
Charging Control Signal Status Charge control signal (CPLT) oscillation state None/Normal/Temporarily Nonusable/Nonusable/Stuck Low/Stuck High - -
Charger Operation Status Electric vehicle charger assembly state output to Hybrid vehicle control ECU assembly Stand by/Ready/Stop - -
Charger Start Request by Hybrid Control ECM Electric vehicle charger assembly activation request (from Hybrid vehicle control ECU assembly) ON or OFF - -
Charger Input Power Electric vehicle charger assembly input power Min.: 0 W, Max.: 327675 W - -
Sub DC/DC Converter Supply Status (for Charging) Sub DC/DC converter state OFF/ON/Abnormal - -
Sub DC/DC Converter Start Request (for Charging) Sub DC/DC converter activation request ON or OFF - -
Target Sub DC/DC Converter Voltage (for Charging) Sub DC/DC converter target output voltage Min: 0.00 V, Max: 79.99 V - -
Charge Canceled by Hybrid Battery WIN Low Trigger Counter Number of times plug-in charging suspended due to drop in WIN of HV battery Min.: 0, Max.: 65535 - -
Charge Canceled by Auxiliary Battery Voltage Low Trigger Counter Number of times plug-in charging suspended due to drop in Battery (12V) voltage Min.: 0, Max.: 65535 - -
Charge Canceled by Charging System Trigger Counter Number of times plug-in charging suspended due to charging system malfunction Min.: 0, Max.: 65535 - -
Charger Power Supply Voltage Decreasing History during Charging Cumulative insufficient power exceeded threshold ON or OFF - -
Charging Power Save Mode History by Charger Temperature High Plug-in charging restricted due to overheating of charging station ON or OFF - -
WIN Low History during Charging Input power dropped during plug-in charging ON or OFF - -
Auxiliary Battery Increasing Electrical Load History during Charging Battery (12V) load exceeded threshold during plug-in charging ON or OFF - -
AC Input Current Charging current sensor value (from charger inlet) Min.: 0.0 A, Max.: 25.5 A - -
AC Charger Rated Power Charging station nominal supply power Min.: -327.68 kW, Max.: 327.67 kW - -
AC Charging Inlet Connect Status Connection state or availability of components connected to plugin charger inlet None/Connecting Charging Connector/Temporarily Nonusable/Nonusable/Not Connect/Connector Not Engaged Properly Status/Connecting External Power Supply Connector - -
AC Charging Input Minimum Voltage History Minimum voltage input during plugin charging history Min.: -3276.8 V, Max.: 3276.7 V - -
AC Charging Negative Relay Drive Request Commanded state of CHRG ON or OFF Battery ECU assembly requesting CHRG relay operation: ON -
AC Charging Positive Relay Drive Request Commanded state of CHRB ON or OFF Battery ECU assembly requesting CHRB relay operation: ON -
AC Charging Precharge Relay Drive Request Commanded state of CHRP ON or OFF Battery ECU assembly requesting CHRP relay operation: ON -
AC Charging Negative Relay Status Operating state of CHRG ON or OFF CHRG relay operating: ON -
AC Charging Positive Relay Status Operating state of CHRB ON or OFF CHRB relay operating: ON -
AC Charging Precharge Relay Status Operating state of CHRP ON or OFF CHRP relay operating: ON -
Operation to Raise AC Charger Rated Current Charging station maximum current supply Increased ON or OFF - -
Operation to Lower AC Charger Rated Current Charging station maximum current supply decreased ON or OFF - -
DC Quick Charging Lid Status Plug-in charger inlet status No Judgment/Close/Open - -
Motor Temperature Sensor "B" Voltage Motor temperature sensor "B" voltage 0 to 4.99 V - -
Motor Temperature "B" Motor temperature "B" Min.: -40°C (-40°F), Max.: 215°C (419°F) Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) While driving: Varies depending on vehicle operating conditions -
Motor Temperature "B" just after IG ON Motor temperature "B" soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Motor Maximum Temperature "B" Maximum Motor temperature "B" after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Shift Switch Status (N, P Position) Shift position status (N or P position) ON or OFF Shift state P or N: ON Shift state
Shift Position Sensor (PNB) Shift position sensor ON or OFF Shift lever in P, N: ON
Shift lever in any position other than P or N
Shift lever position sensor
Shift Position Sensor (PR) Shift position sensor ON or OFF Shift lever in P or R: ON
Shift lever in any position other than P or R: OFF
Shift lever position sensor
Shift Position Sensor (DB1) Shift position sensor ON or OFF Shift lever in D or S: ON
Shift lever in any position other than D or S: OFF
Shift lever position sensor
Shift Position Sensor (DB2) Shift position sensor ON or OFF Shift lever in D or S: ON
Shift lever in any position other than D or S: OFF
Shift lever position sensor
Shift Position Sensor (N) Shift position sensor ON or OFF Shift lever in N: ON
Shift lever in any position other than N: OFF
Shift lever position sensor
Shift Position Sensor (R) Shift position sensor ON or OFF Shift lever in R: ON
Shift lever in any position other than R: OFF
Shift lever position sensor
Shift Position Sensor (P) Shift position sensor ON or OFF Shift lever in P: ON
Shift lever in any position other than P: OFF
Shift lever position sensor