  Troubleshooting     
Defect  Possible cause  Notes  Remedy 
1 Voltage supply at terminal 15   AD77.50-P-6000-04A 
Indicator lamp in vario roof switch (S84) is not illuminated when ignition switched on Vario roof switch (S84)   AD77.50-P-6000-16A 
  Multi-function control module (N10-3)   N10-3
2 Trunk partition "closed" limit switch (S69/10)   AD77.50-P-6000-14A 
Indicator lamp in vario roof switch (S84) flashes at 6 times normal frequency (pulsing) when switch operated Trunk lid "closed" limit switch (S69/12)   AD77.50-P-6000-15A 
3 Left trunk lid "closed/locked" limit switch (S69/7) not actuated   AD77.50-P-6000-13A 
Indicator lamp in vario roof switch flashes when vario roof open (no pulsing) (gong sounds when vehicle moving) Right trunk lid "closed/locked" limit switch (S69/8) not actuated   AD77.50-P-6000-13A 
  Vario roof "locked" limit switch (left rotary tumbler) (S69/3) not actuated   AD77.50-P-6000-09A 
  Vario roof "locked" limit switch (right rotary tumbler) (S69/2) not actuated
After 6.5 minutes in the stop mode, the gong in the instrument cluster is energized for 30 s
  AD77.50-P-6000-09A 
4 Left trunk lid "closed/locked" limit switch (S69/7) not actuated   AD77.50-P-6000-13A 
Indicator lamp in vario roof switch flashes (pulsing) when switch not operated Right trunk lid "closed/locked" limit switch (S69/8) not actuated   AD77.50-P-6000-13A 
  Vario roof "locked" limit switch (left rotary tumbler) (S69/3) not actuated   AD77.50-P-6000-09A 
  Vario roof "locked" limit switch (right rotary tumbler) (S69/2) not actuated
After 6.5 minutes in the stop mode, the gong in the instrument cluster is energized for 30 s
  AD77.50-P-6000-09A 
5
Indicator lamp in vario roof switch flashes (pulsing) when switch operated
Fault is identified (fault details stored)   Read out fault memory with Hand-Held Tester (HHT)
6 Left trunk lid "closed/locked" limit switch (S69/7) not actuated   AD77.50-P-6000-13A 
Indicator lamp in vario roof switch illuminated when roof locked (no pulsing) (gong sounds when vehicle moving) Right trunk lid "closed/locked" limit switch (S69/8) not actuated   AD77.50-P-6000-13A 
  Vario roof "locked" limit switch (left rotary tumbler) (S69/3) not actuated   AD77.50-P-6000-09A 
  Vario roof "locked" limit switch (right rotary tumbler) (S69/2) not actuated   AD77.50-P-6000-09A 
7 Hydraulic unit not running   AD77.50-P-6000-06A 
During opening procedure of vario roof: Trunk partition "closed" limit switch (S69/10)   AD77.50-P-6000-07A 
front and rear side windows are not retracted Trunk lid rotary tumbler/trunk lamp toggle   AD77.50-P-6000-14A 
  switch (S69/12)   AD77.50-P-6000-15A 
  Left or right trunk lid "closed/locked" limit   AD77.50-P-6000-12A 
  switch (S69/7 or S69/8) and trunk lid "open"   AD77.50-P-6000-13A 
  limit switch (S69/9) are actuated   AD77.50-P-6000-10A 
  simultaneously   AD77.50-P-6000-11A 
  Vario roof "open/lowered" limit switch (S69/11)   AD77.50-P-6000-09A 
  and vario roof "closed" limit switch (S69/1) are   AD77.50-P-6000-10A 
  actuated simultaneously   AD77.50-P-6000-11A 
  Left or right vario roof "locked" limit switch   AD77.50-P-6000-10A 
  (S69/3 or S69/2) is actuated, whereas vario roof   AD77.50-P-6000-11A 
  "open/lowered" limit switch (S69/11) and vario   AD77.50-P-6000-13A 
  roof "closed" limit switch (S69/1) are not   AD77.50-P-2000-07A 
  actuated   AD77.50-P-2000-08A 
  Left or right trunk lid "closed/locked" limit   AD77.50-P-2000-09A 
  switch (S69/7 or S69/8) is actuated, whereas   AD77.50-P-2000-10A 
  vario roof "open/lowered" limit switch (S69/11)   AD77.50-P-6000-19A 
  and vario roof "closed" limit switch (S69/1) are   AD77.50-P-6000-20A 
  not actuated   AD77.50-P-6000-21A 
  No limit switch signal present   AD77.50-P-6000-22A 
  Voltage supply for power windows   AD77.50-P-6000-23A 
  Speed signal   AD77.50-P-6000-24A 
  Signal Temperature Pump   AD77.50-P-6000-25A 
  Switch Vario-Roof (S84)   AD77.50-P-6000-26A 
  Multi-function control unit (N10-3)   AD77.50-P-6000-27A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-28A 
  Trunk Lid Solenoid valve (A7/5y2)   AD77.50-P-6000-29A 
AD77.50-P-6000-30A 
AD77.50-P-6000-34A 
AD77.50-P-6000-35A 
AD77.50-P-6000-08A 
AD77.50-P-6000-17A 
AD77.50-P-6000-02A 
AD77.50-P-6000-05A 
AD77.50-P-6000-31A 
AD77.50-P-6000-32A 
8 Trunk lid rotary tumbler/trunk lamp toggle switch (S69/12)   AD77.50-P-6000-15A 
Vario roof is not released at front Trunk partition "closed" limit switch (S69/10)
Vario roof "locked" limit switch (left rotary tumbler) (S69/3)
  AD77.50-P-6000-14A 
  Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Vario roof "open/lowered" limit switch (S69/11)
Trunk lid "open" limit switch (S69/9)
  AD77.50-P-6000-09A 
  Left trunk lid "closed/locked" limit switch   AD77.50-P-6000-11A 
  (S69/7)   AD77.50-P-6000-12A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-13A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-06A 
  Trunk lid cylinder (A7/5y2)   AD77.50-P-6000-07A 
  Check vario roof hydraulic cylinder   AD77.50-P-6000-31A 
AD77.50-P-6000-32A 
AD77.50-P-7000-04A 
9 Trunk lid rotary tumbler/trunk lamp toggle switch (S69/12)   AD77.50-P-6000-15A 
Trunk lid is not released or does not open Trunk partition "closed" limit switch (S69/10)
Vario roof "locked" limit switch (left rotary tumbler) (S69/3)
  AD77.50-P-6000-14A 
  Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Vario roof "open/lowered" limit switch (S69/11)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)
Left trunk lid "closed/locked" limit switch
  AD77.50-P-6000-11A 
  (S69/7)   AD77.50-P-6000-12A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-13A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-06A 
  Trunk lid cylinder solenoid valve (A7/5y2)   AD77.50-P-6000-07A 
  Check vario roof hydraulic cylinder   AD77.50-P-6000-31A 
AD77.50-P-6000-32A 
AD77.50-P-7000-04A 
10 Trunk lid rotary tumbler/trunk lamp toggle switch (S69/12)   AD77.50-P-6000-15A 
Vario roof does not open Trunk partition "closed" limit switch (S69/10)
Left trunk lid "closed/locked" limit switch (S69/7)
  AD77.50-P-6000-14A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Vario roof "open/lowered" limit switch (S69/11)   AD77.50-P-6000-13A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-11A 
  Trunk lid cylinder (A7/5y2)   AD77.50-P-6000-06A 
  Check vario roof hydraulic cylinder   AD77.50-P-6000-07A 
AD77.50-P-6000-32A 
AD77.50-P-7000-04A 
11 Trunk lid rotary tumbler/trunk lamp toggle switch (S69/12)   AD77.50-P-6000-15A 
Trunk lid does not close or lock Trunk partition "closed" limit switch (S69/10)
Left trunk lid "closed/locked" limit switch (S69/7)
  AD77.50-P-6000-14A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-13A 
  Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-09A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-12A 
      AD77.50-P-6000-06A 
  Check trunk lid hydraulic cylinder   AD77.50-P-6000-07A 
AD77.50-P-7000-05A 
12 Voltage supply for power windows   AD77.50-P-6000-19A 
Side windows not raised after vario roof opening procedure     AD77.50-P-6000-20A 
AD77.50-P-6000-21A 
AD77.50-P-6000-22A 
AD77.50-P-6000-23A 
AD77.50-P-6000-24A 
AD77.50-P-6000-25A 
AD77.50-P-6000-26A 
AD77.50-P-6000-27A 
AD77.50-P-6000-28A 
AD77.50-P-6000-29A 
AD77.50-P-6000-30A 
  Trunk lid rotary tumbler/trunk lamp toggle switch (S69/12)   AD77.50-P-6000-15A 
  Trunk partition "closed" limit switch (S69/10)   AD77.50-P-6000-14A 
  Left trunk lid "closed/locked" limit switch (S69/7)   AD77.50-P-6000-13A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-09A 
  Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-12A 
  Multi-function control module (N10-3)   AD77.50-P-6000-02A 
AD77.50-P-6000-05A 
13 Hydraulic unit does not run   AD77.50-P-6000-06A 
During vario roof closing procedure: vario roof does not close Trunk lid rotary tumbler/trunk lamp toggle   AD77.50-P-6000-07A 
  switch (S69/12)   AD77.50-P-6000-15A 
  Trunk partition "closed" limit switch (S69/10)   AD77.50-P-6000-14A 
  Left or right trunk lid "closed/locked" limit   AD77.50-P-6000-12A 
  switch (S69/7 or S69/8) and trunk lid "open"   AD77.50-P-6000-13A 
  limit switch (S69/9) are actuated   AD77.50-P-6000-10A 
  simultaneously   AD77.50-P-6000-11A 
  Vario roof "open/lowered" limit switch (S69/11)   AD77.50-P-6000-09A 
  and vario roof "closed" limit switch (S69/1) are   AD77.50-P-6000-10A 
  actuated simultaneously   AD77.50-P-6000-11A 
  Left or right vario roof "locked" limit switch   AD77.50-P-6000-10A 
  (S69/3 or S69/2) is actuated, whereas vario roof   AD77.50-P-6000-11A 
  "open/lowered" limit switch (S69/11) and vario   AD77.50-P-6000-13A 
  roof "closed" limit switch (S69/1) are not   AD77.50-P-2000-07A 
  actuated   AD77.50-P-2000-08A 
  Left or right trunk lid "closed/locked" limit   AD77.50-P-2000-09A 
  switch (S69/7 or S69/8) is actuated, whereas   AD77.50-P-2000-10A 
  vario roof "open/lowered" limit switch (S69/11)   AD77.50-P-6000-19A 
  and vario roof "closed" limit switch (S69/1) are   AD77.50-P-6000-20A 
  not actuated   AD77.50-P-6000-21A 
AD77.50-P-6000-22A 
  No limit switch signal present   AD77.50-P-6000-23A 
  Voltage supply for power windows   AD77.50-P-6000-24A 
  Speed signal   AD77.50-P-6000-25A 
  Signal Temperature Pump   AD77.50-P-6000-26A 
  Switch Vario-Roof (S84)   AD77.50-P-6000-27A 
  Multi-function control unit (N10-3)   AD77.50-P-6000-28A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-29A 
  Trunk Lid Solenoid valve (A7/5y2)   AD77.50-P-6000-30A 
AD77.50-P-6000-34A 
AD77.50-P-6000-35A 
AD77.50-P-6000-08A 
AD77.50-P-6000-17A 
AD77.50-P-6000-01A 
AD77.50-P-6000-03A 
AD77.50-P-6000-04A 
AD77.50-P-6000-31A 
AD77.50-P-6000-32A 
14 Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-09A 
Trunk lid is not released or does not open Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-12A 
  Left trunk lid "closed/locked" limit switch (S69/7)   AD77.50-P-6000-13A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Trunk partition "closed" limit switch (S69/10)
Trunk lid rotary tumbler/trunk lamp toggle switch (S69/12)
  AD77.50-P-6000-14A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-15A 
AD77.50-P-6000-06A 
  Trunk lid cylinder (A7/5y2)   AD77.50-P-6000-07A 
  Check vario roof hydraulic cylinder   AD77.50-P-6000-32A 
AD77.50-P-7000-04A 
15 Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-09A 
Vario roof is not released Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-12A 
  Left trunk lid "closed/locked" limit switch (S69/7)   AD77.50-P-6000-13A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Trunk partition "closed" limit switch (S69/10)
Trunk lid rotary tumbler/trunk lamp toggle switch (S69/12)
  AD77.50-P-6000-14A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-15A 
AD77.50-P-6000-06A 
  Trunk lid cylinder (A7/5y2)   AD77.50-P-6000-07A 
AD77.50-P-6000-32A 
16 Vario roof "closed" limit switch (S69/1)   AD77.50-P-6000-10A 
Vario roof does not close Vario roof "open/lowered" limit switch (S69/11)
Hydraulic pump (A7/5)
  AD77.50-P-6000-11A 
AD77.50-P-6000-06A 
  Vario roof solenoid valve (A7/5y1)
Trunk lid cylinder (A7/5y2)
  AD77.50-P-6000-07A 
  Check hydraulic cylinder   AD77.50-P-6000-32A 
AD77.50-P-7000-01A 
17 Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-09A 
Trunk lid does not close or lock Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-12A 
  Left trunk lid "closed/locked" limit switch (S69/7)   AD77.50-P-6000-13A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-07A 
AD77.50-P-6000-06A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-31A 
  Check vario roof hydraulic cylinder   AD77.50-P-7000-07A 
18 Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-09A 
Vario roof does not lock Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-12A 
  Left trunk lid "closed/locked" limit switch (S69/7)   AD77.50-P-6000-13A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-06A 
AD77.50-P-6000-07A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-31A 
  Check trunk lid hydraulic cylinder   AD77.50-P-7000-05A 
19 Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-09A 
Rear side windows are not raised Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-12A 
  Left trunk lid "closed/locked" limit switch (S69/7)   AD77.50-P-6000-13A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Voltage supply for power windows   AD77.50-P-6000-19A 
AD77.50-P-6000-20A 
AD77.50-P-6000-21A 
AD77.50-P-6000-22A 
AD77.50-P-6000-23A 
AD77.50-P-6000-24A 
AD77.50-P-6000-25A 
AD77.50-P-6000-26A 
AD77.50-P-6000-27A 
AD77.50-P-6000-28A 
AD77.50-P-6000-29A 
AD77.50-P-6000-30A 
AD77.50-P-6000-27A 
  Multi-function control module (N10-3)   AD77.50-P-6000-29A 
AD77.50-P-6000-06A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-07A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-31A 
20 Vario roof "locked" limit switch (left rotary tumbler) (S69/3)   AD77.50-P-6000-09A 
Front side windows are not raised Vario roof "locked" limit switch (right rotary tumbler) (S69/2)   AD77.50-P-6000-09A 
  Trunk lid "open" limit switch (S69/9)   AD77.50-P-6000-12A 
  Left trunk lid "closed/locked" limit switch (S69/7)   AD77.50-P-6000-13A 
  Right trunk lid "closed/locked" limit switch (S69/8)   AD77.50-P-6000-13A 
  Voltage supply for power windows   AD77.50-P-6000-19A 
AD77.50-P-6000-20A 
AD77.50-P-6000-21A 
AD77.50-P-6000-22A 
AD77.50-P-6000-23A 
AD77.50-P-6000-24A 
AD77.50-P-6000-25A 
AD77.50-P-6000-26A 
AD77.50-P-6000-27A 
AD77.50-P-6000-28A 
AD77.50-P-6000-29A 
AD77.50-P-6000-30A 
AD77.50-P-6000-21A 
  Multi-function control module (N10-3)   AD77.50-P-6000-25A 
AD77.50-P-6000-06A 
  Hydraulic pump (A7/5)   AD77.50-P-6000-07A 
  Vario roof solenoid valve (A7/5y1)   AD77.50-P-6000-31A 
21 Vario roof not locked   AD77.50-P-6000-09A 
AD77.50-P-6000-13A 
Side windows are not opened or closed by vario roof switch (S84) but can be operated by power window switch Vario roof switch (S84)   AD77.50-P-6000-17A 
  Multi-function control module (N10-3)   AD77.50-P-6000-21A 
AD77.50-P-6000-25A 
22 Left front power window switch (S21/1)   AD77.50-P-6000-20A 
Side windows are not opened or closed by power window switch (position 1) Right front power window switch (S21/2)   AD77.50-P-6000-24A 
  Left front power window motor (M10/3)   AD77.50-P-6000-22A 
  Right front power window motor (M10/4)   AD77.50-P-6000-26A 
  Multi-function control module (N10-3)   AD77.50-P-6000-19A 
AD77.50-P-6000-23A 
23 Left front power window switch (S21/1)   AD77.50-P-6000-20A 
Side windows are not opened automatically by power window switch (position 2) Right front power window switch (S21/2)   AD77.50-P-6000-24A 
  Multi-function control module (N10-3)   AD77.50-P-6000-19A 
AD77.50-P-6000-23A 
24
Vario roof opening or closing procedure too slow
Check hydraulic unit   AD77.50-P-7000-01A