Heating, Air Conditioning & Ventilation - With Diagnostics - Lancer
- General Description
- General Specifications
- Service Specifications
- Lubricants
- Service Precautions
- Manual A/C Diagnosis
- Introduction To Heater, A/C And Ventilation Diagnosis
- Heater, A/C And Ventilation Diagnostic Troubleshooting Strategy
- Diagnostic Function
- Diagnostic Trouble Code Table
- Diagnostic Trouble Code Procedures
- DTC B1003: Mode Dial SW Error < Vehicles without A/C >
- DTC B1003: Mode Dial SW Error < Vehicles with A/C >
- DTC B1018: Temperature Control Dial SW Error < Vehicles without A/C >
- DTC B1018: Temperature Control Dial SW Error < Vehicles with A/C >
- DTC B1021: Fan Dial SW Error < Vehicles without A/C >
- DTC B1021: Fan Dial SW Error < Vehicles with A/C >
- DTC B1031, B1032: Air Thermo Sensor System < Vehicles without A/C >
- DTC B1031, B1032: Air Thermo Sensor System < Vehicles with A/C >
- DTC B1034, B1035: Ambient air temperature Sensor System
- DTC B1079: Refrigerant Leaks
- DTC U1415: Coding Not Completed
- DTC U0019: Bus Off (CAN1)
- DTC U0141: ETACS-ECU Time-out
- DTC U0151: SRS-ECU Time-out
- DTC U0154: Occupant classification ECU time out
- DTC U0155: Combination meter Time-out
- DTC U0168: WCM Time-out
- Symptom Chart < Vehicles Without A/C >
- Symptom Procedures < Vehicles Without A/C >
- INSPECTION PROCEDURE 1: Malfunction of the heater controller assembly (A/C-ECU) Power Supply System
- INSPECTION PROCEDURE 2: Blower fan and motor do not turn
- INSPECTION PROCEDURE 3: Blower air amount cannot be changed
- INSPECTION PROCEDURE 4: Outside/inside air changeover is not possible
- INSPECTION PROCEDURE 5: A/C outlet air temperature does not increase
- INSPECTION PROCEDURE 6: Air outlet vent cannot be changed. < Vehicles without A/C >
- INSPECTION PROCEDURE 7: Blower motor power supply system
- Symptom Chart < Vehicles With A/C >
- Symptom Procedures < Vehicles With A/C >
- INSPECTION PROCEDURE 1: When the A/C is Operation, Temperature Inside the Passenger Compartment does not Decrease (Cool Air is not Emitted)
- INSPECTION PROCEDURE 2: Malfunction of the A/C controller assembly (A/C-ECU) Power Supply System
- INSPECTION PROCEDURE 3: The Compressor does not Work
- INSPECTION PROCEDURE 4: Blower Fan and Motor do not Turn
- INSPECTION PROCEDURE 5: Blower Air Amount cannot be Changed
- INSPECTION PROCEDURE 6: Outside/Inside Air Changeover is not possible
- INSPECTION PROCEDURE 7: A/C Outlet Air Temperature does not Increase
- INSPECTION PROCEDURE 8: Air Outlet Vent cannot be Changed
- INSPECTION PROCEDURE 9: Blower Motor power supply system
- Data List Reference Table
- Actuator Test Reference
- Check At A/C-Ecu Terminal < Vehicles Without A/C >
- Check At A/C-Ecu Terminal < Vehicles With A/C >
- Special Tools
- On-Vehicle Service
- Heater Control Unit
- Heater Unit And Blower Assembly
- Motors And Transistor
- Ambient Air Temperature Sensor
- Compressor Assembly
- Condenser Assembly
- Refrigerant Line
- Ducts
- Ventilators