Vario roof (VR) diagnosis, previous knowledge - AD77.50-P-2000A: Notes
MODEL 170
| Risk of injury in the form of trapping or crushing when working on preloaded springs or spring devices | Use only the approved clamping devices, and cordon off the danger zone if appropriate. Check special tools for damage and correct functioning (visual inspection). |
AS00.00-Z-0001-01A | |
| Risk of injury in the form of trapping or crushing , or even severing of limbs, if caught in the mechanism | When moving the components, no parts of the body or limbs may be within the mechanism's range of movement. | AS00.00-Z-0009-01A | |
| Risk of injury as a result of trapping or crushing when working on the partly open vario roof (stop mode) or within its closing range as a result of the vario roof suddenly collapsing | Secure the vario roof with a suitable special tool. | AS77.50-Z-0001-01A | |
| Before operating the vario roof, the sun shade in the trunk must be drawn and the trunk lid closed | |||
| Using and connecting up test devices | AD00.00-P-1000AZ | ||
| Summary of electric circuit diagrams, sliding roof, soft top | PE77.00-P-1100B | ||
| Vario roof (VR), position of electrical components | GF77.30-P-0001-01A | ||
| Vario roof (VR), position of hydraulic components | GF77.30-P-0001-02A | ||
| Vario roof (VR), interconnection of components | GF77.30-P-0001-03A | ||
| Tools, diagnosis of electrical system, vario roof (VR) | AD77.50-P-2000-01A | ||
| Tools, diagnosis of hydraulic system, vario roof (VR) | AD77.50-P-2000-02A | ||
| Variant coding, vario roof (VR) | AD77.50-P-2000-03A | ||
| Socket box connection diagram, vario roof (VR) | AD77.50-P-2000-04A | ||
| Notes on hydraulic testing, vario roof (VR) | AD77.50-P-2000-05A | ||
| Connection diagram between pressure gauge and hydraulic unit for vario roof (VR) | AD77.50-P-2000-06A | ||
| Summary chart, electric limit-switch constellation for opening procedure of vario roof | AD77.50-P-2000-07A | ||
| Summary chart, electric limit-switch constellation for closing procedure of vario roof | AD77.50-P-2000-08A | ||
| Summary chart, energizing side windows for opening procedure of vario roof | AD77.50-P-2000-09A | ||
| Summary chart, energizing side windows for closing procedure of vario roof | AD77.50-P-2000-10A | ||
| Circuit diagram for hydraulic unit, diagnosis with previous knowledge of vario roof (VR) | AD77.50-P-2000-11A | ||
| Circuit diagram for system pressure, diagnosis with previous knowledge of vario roof (VR) | AD77.50-P-2000-12A | ||
| Circuit diagram for hydraulic unit delivery rate, diagnosis with previous knowledge of vario roof (VR) | AD77.50-P-2000-13A | ||
| Circuit diagram for hydraulic cylinders, vario roof end of rod, diagnosis with previous knowledge of vario roof (VR) | AD77.50-P-2000-14A | ||
| Circuit diagram for hydraulic cylinders, trunk lid end of rod, diagnosis with previous knowledge of vario roof (VR) | AD77.50-P-2000-15A | ||
| Circuit diagram for hydraulic cylinders, rod end for front catch, diagnosis with previous knowledge of vario roof (VR) | AD77.50-P-2000-16A | ||
| Circuit diagram for hydraulic cylinders, vario roof end of plunger, diagnosis with previous knowledge of vario roof (VR) | AD77.50-P-2000-17A | ||
| Instructions for stopper for vario roof (VR) | AD77.50-P-2000-18A | ||
| Catches for tubular frame in trunk, vario roof (VR) | AD77.50-P-2000-19A | ||
| Locking to C-post, vario roof (VR) | AD77.50-P-2000-20A | ||
| Connection diagram for hydraulic cylinder, vario roof (VR) | AD77.50-P-2000-21A | ||
| Circuit diagram (folding roof closed) for hydraulic cylinder, vario roof (VR) | AD77.50-P-2000-22A | ||
| Operational sequence, opening vario roof (VR) | AD77.50-P-2000-23A | ||
| Operational sequence, closing vario roof (VR) | AD77.50-P-2000-24A | ||
| Summary chart, energizing of solenoid valves for vario roof opening procedure | AD77.50-P-2000-25A | ||
| Summary chart, energizing of solenoid valves for vario roof closing procedure | AD77.50-P-2000-26A | ||
| Note on fault memory, vario roof (VR) | AD77.50-P-2000-27A |