LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2020 >> S560e >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Central Locking System - 222 Chassis (1 Of 2) >> Basic Knowledge >> Anti-Theft Alarm System, Basic Function - GF80.50-P-9900A

Anti-Theft Alarm System, Basic Function - GF80.50-P-9900A

Model All (CAR) 

Overview 

This document contains the following information:

General 

The ATA monitors the status of all alarm inputs after the locking of the vehicle via the central locking system (CL).

If an opening is detected, the ATA outputs a visual and audible alarm signal.

The anti-theft alarm system monitors:

The status (open or closed) of the doors, hood and trunk lid or tailgate is detected by microswitches and queried on a cyclical basis every 200 ms.

Vehicles with interior protection 

The interior protection and/or tow-away protection can be deactivated before the vehicle is locked. The interior protection and/or tow-away protection is only deactivated for the subsequent activation of the antitheft alarm system.

Activating ATA 

The anti-theft alarm system is activated when the vehicle is locked. All alarm inputs are armed. The ATA function indicator shows this status and flashes.

IMPORTANT If the driver's door is still open when the vehicle is locked, its remains unlocked. The alarm input is armed once the driver's door is closed. An alarm is triggered if the driver's door is opened.

The following components are additionally activated on vehicles with interior protection:

The alarm siren is armed together with the ATA and is addressed on a cyclical basis approx. every 600 ms.

Automatic activation of ATA (code 552 (Self-arming)) 

If the driver's door, trunk lid, or tailgate is opened and closed again after the ignition is switched off, the ATA arms itself automatically after 100 s.

IMPORTANTDeactivating ATA: 

The ATA is deactivated when the vehicle is unlocked via the transmitter key or where the start/stop button is actuated.

Trigger ATA alarm 

An ATA alarm is triggered by:

Opening of a door, hood or trunk lid or tailgate 

An alarm is triggered if one of the microswitches that monitors the status of the doors, hood or trunk lid or tailgate exits its idle state. The corresponding microswitch must first return to its idle state before an alarm can be triggered again. After approx. 10 s, the same microswitch can trigger an alarm again if no audible alarm signal is pending.

IMPORTANT If a locked vehicle is unlocked with the emergency key and the door is opened, the ATA triggers an alarm.

Movement in vehicle interior (vehicles with interior protection) 

If a movement is detected in the vehicle interior and is classified as alarm relevant, the ATA triggers an alarm.

The sensitivity of the interior protection is reduced in the case of the following situations:

The interior protection is temporarily deactivated if automated functions can lead to the triggering of an ATA alarm.

Examples of such functions are:

Change in vehicle inclination (tow-away protection) (vehicles with interior protection) 

If the inclination quickly changes with regard to the reference position, the ATA triggers an alarm. An alarm is already output before a wheel loses contact with the ground where a vehicle is lifted.

To prevent inadvertent activations in the case of very slow changes in the inclination (e.g. tire malfunction), the reference position is in this connection compared with the current inclination. In the case of an inclination sensor defect, all other ATA components remain fully operational.

Glass breakage (vehicles with glass breakage sensor(s) and interior protection) 

If an open circuit is detected in the induction loop in the associated rear side window (station wagons and SUVs) or in the rear window, the ATA triggers an alarm.

The glass breakage sensors are connected in series. The interruption of the induction loop of an additional glass breakage sensor does not trigger an alarm.

Loss of communication with alarm siren (vehicles with interior protection) 

If the alarm siren does not respond to the cyclical addressing within 1 s (no communication), the ATA triggers an alarm.

If the alarm siren detects a loss in the supply voltage, an audible alarm signal is also automatically output.

Panic alarm (radio remote control with panic alarm) 

An alarm is triggered by pressing the panic alarm button on the transmitter key for approx. 2 s. The alarm is canceled again by briefly pressing the panic alarm again on the transmitter key.

Output ATA alarm 

Visual alarm 

When an ATA alarm is triggered, the hazard warning system is activated and the interior lighting is switched on. In vehicles with ambient lighting, the ambient lighting flashes blue and red. The visual alarm is active for 5 min.

Acoustic alarm 

The acoustic alarm signal is output in vehicles with interior protection via the alarm siren. In vehicles without interior protection, the acoustic alarm signal is output via the horn. The acoustic alarm signal is active for 30 s.

The audible alarm signal is increased to 5 min under the following conditions:

The alarm output is canceled via the following actions:

  Function schematics     
  Function schematic for triggering of anti-theft alarm system alarm Model 118, 177, 243, 247 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2500-97A
    Model 167, 293 with code 551 (Standard antitheft alarm system (ATA)) PE80.50-P-2500-97B
    Model 206, 223, 254, 297 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2500-97C
    Model 213, 238, 257, 290 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2500-97D
    Model 295, 296 with code 551 (Standard antitheft alarm system (ATA)) PE80.50-P-2500-97E
    Model 232 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2500-97F
  Function schematic for output of anti-theft alarm system alarm Model 118, 167, 177, 243, 247, 293 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2501-97A
    Model 206, 223, 254, 297 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2501-97B
    Model 213, 238, 257, 290 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2501-97C
    Model 295, 296 with code 551 (Standard antitheft alarm system (ATA)) PE80.50-P-2501-97D
    Model 232 with code 551 (Standard anti-theft alarm system (ATA)) PE80.50-P-2501-97E
  Additional basic functions     
  Authorization of transmitter key/mobile phone, basic function   GF80.20-P-1004A 
  Basic function of signal acquisition and actuation module Model 118, 177, 243, 247 GF54.21-P-9895A
  Basic function of signal acquisition and actuation module at front Model 167, 206, 223, 232, 254, 293, 295, 296, 297
Model 213, 238, 257, 290 as of model year 2021
GF54.21-P-9896A
  Front door control unit, basic function   GF72.29-P-9891A
  Rear door control unit, basic function   GF72.29-P-9892A
  Overhead control panel control unit, basic function   GF82.20-P-9890A
  Trunk lid/liftgate lock, basic function   GF80.20-P-2012A 
  Door lock, basic function   GF80.20-P-2017A 
  Transmitter key, basic function   GF80.35-P-2001A 
  Alarm siren, basic function   GF80.50-P-2008A 
  Glass breakage sensor, basic function   GF80.50-P-2009A