ME-SFI ignition system, testing of electrical system - AD07.61-P-6001B
ENGINES 113.940 /942 /943 up to 31.5.00, 113.961
| Hazard from contact with parts conducting high voltages. | Do not touch parts which conduct high voltages. Persons who wear electronic implants (e.g. heart pacemakers) must not carry out work on the ignition system. | AS15.10-Z-0001-01A | |
| Lethal hazard from being drawn into rotating vehicle parts | Do not reach into rotating parts. Wear closed and close-fitting work clothes. Secure area of rotating vehicle components against unauthorized access. |
AS00.00-Z-0004-01A | |
| Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel. | No fire, sparks, naked flames or smoking. Pour fuels only into suitable and appropriately marked containers. Wear protective clothing when handling fuel. |
AS47.00-Z-0001-01A | |
| When disconnecting the connectors on the ME-SFI control module, disconnect the middle connector first and when connecting, connect the middle connector D last. | |||
| Connection and use of testing equipment | AD00.00-P-1000AZ | ||
| Gasoline injection and ignition system (ME-SFI) diagnosis - prerequisites | AD07.61-P-2000B | ||
| Tools for gasoline injection and ignition system, testing of electrical system | AD07.61-P-2000-06A | ||
| Connector assignment for ME-SFI gasoline injection and ignition system | AD07.61-P-2000-02B | ||
| Notes on gauge/test connection column The numbers entered in parentheses, such as, for example in => 1.0 (2A) have the following meaning: A = Connector A in the circuit diagram 2 = Socket 2 in the circuit diagram |
|||
| Gasoline injection and ignition system (ME-SFI) diagnosis - diagnostic trouble code memory | Fault codes from P0000 to P0304 | AD07.61-P-4000B | |
| Gasoline injection and ignition system (ME-SFI) diagnosis - diagnostic trouble code memory | Fault codes from P0305 to P0743 | AD07.61-P-4000BA | |
| Gasoline injection and ignition system (ME-SFI) diagnosis - diagnostic trouble code memory | Fault codes from P0748 to P1747 | AD07.61-P-4000BB | |
| a | Ignition: OFF | ||
| b | Connect test wiring harness with socket box at ME-SFI control module (N3/10) according to connection diagram. | ||
| Checking | |||
| 1 | ME-SFI control module terminal 30, testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-01B | |
| 2 | ME-SFI control module terminal 87, testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-02B | |
| 3 | Ignition coil (T1/1), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-03B | |
| 4 | Ignition coil (T1/2), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-04B | |
| 5 | Ignition coil (T1/3), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-05B | |
| 6 | Ignition coil (T1/4), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-06B | |
| 7 | Ignition coil (T1/5), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-07B | |
| 8 | Ignition coil (T1/6), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-08B | |
| 9 | Ignition coil (T1/7), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-18A | |
| 10 | Ignition coil (T1/8), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-19A | |
| 11 | Crankshaft position sensor, testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-09B | |
| 12 | Camshaft Hall sensor, testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-10B | |
| 13 | Primary voltage (T1/1), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-11A | |
| 14 | Primary voltage (T1/2), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-12B | |
| 15 | Primary voltage (T1/3), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-13B | |
| 16 | Primary voltage (T1/4), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-14B | |
| 17 | Primary voltage (T1/5), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-15B | |
| 18 | Primary voltage (T1/6), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-16B | |
| 19 | Primary voltage (T1/7), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-20A | |
| 20 | Primary voltage (T1/8), testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-21A | |
| 21 | Ignition voltage, testing of electrical system, ME-SFI ignition system | AD07.61-P-6001-17B |