Install the positive battery cable from the remote positive terminal to the alternator
- Insert the positive battery cable (2).
- Engage the positive battery cable (2) on the detents (1).
- Feed in the positive battery cable (2) on the stud bolt on the alternator.
- Tighten nut (1).
TIGHTENING TORQUES SPECIFICATION
| Positive battery cable to alternator | ||
| Nut M8 | Tightening torque | 19 Nm |
- Insert the cover of the positive battery cable (1).
- Engage the positive battery cable on the holders (1).
- Feed in the positive battery cable (2) on the stud bolt on the remote positive terminal.
- Tighten nut (1).
TIGHTENING TORQUES SPECIFICATION
| Positive battery cable | ||
| Positive pole screw | tightening torque | 15 Nm |
- Feed in the cover (1) in a downwards direction.
- Check the detents (2) are seated correctly.
Follow-up work
- Refer to SECURING WIRING HARNESS TO CYLINDER BANK 1 .
- Refer to INSTALLING CLEAN AIR PIPE OF CYLINDER BANK 1 .
- Refer to INSTALLING THE CLEAN AIR PIPE OF CYLINDER BANK 2 .
- Refer to INSTALLING LEFT INTAKE SILENCER HOUSING .
- Refer to TIGHTENING THE LEFT FRONT-END STRUT .
- Refer to INSTALLING RIGHT INTAKE SILENCER HOUSING .
- Refer to TIGHTENING THE FRONT-END STRUT ON THE RIGHT .
- Refer to INSTALLING THE COVER IN THE ENGINE COMPARTMENT ON THE RIGHT .
- Refer to INSTALLING THE COVER IN THE ENGINE COMPARTMENT ON THE LEFT .
- Refer to INSTALLING CONTROL UNIT HOLDER FOR CYLINDERS 1 TO 4 .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to INSTALLING THE COVER PANEL OF THE SLAVE DME CONTROL UNIT .
- Refer to INSTALLING THE COVER PANEL OF THE MASTER DME CONTROL UNIT .
- Installing the cover panel of the master DME control unit.
- Position the cover of the master DME control unit (1)
- Engage the cover panel of the master DME control unit (1) downwards with the clamps (2) and the guide pins (3) in the carrier plate of the DME.
- Refer to CONNECTING BATTERY GROUND LEAD .