Installing control unit holder for cylinders 1 to 4
- Insert and position control unit holder (1) with the control units.
- Make sure that the centering pins (2) are located in the rubber mounts (1).
- Engage the cable bracket (1).
- Connect connectors (1) and lock.
- Connect connectors (1) and lock.
- Engage the wires and connectors (1) to the adapter plate.
- Tighten down screw (1).
TIGHTENING TORQUES SPECIFICATION
| DME control unit holder | ||
| screw | Tightening torque | 8 Nm |
- Tighten down screw (1).
TIGHTENING TORQUES SPECIFICATION
| DME control unit holder | ||
| screw | Tightening torque | 8 Nm |
- Engage the cable bracket (2).
Follow-up work
- Refer to INSTALLING ACOUSTIC COVER .
- Installing the cover panel of the master DME control unit.
- Position the cover of the master DME control unit (1)
- Engage the cover panel of the master DME control unit (1) downwards with the clamps (2) and the guide pins (3) in the carrier plate of the DME.
- Refer to CONNECTING BATTERY GROUND LEAD .