Re-programming air-conditioning control unit
Preliminary Work:
- Increased current draw during diagnosis or control unit programming can cause a drop in voltage, which can result in one or more fault entries and the abnormal termination of the programming process.
→ Before starting control unit programming, connect a suitable battery charger or power supply, suitable for AGM type batteries, recommended current rating of 70A fixed voltage 13.5V to 14.5V.
- An unstable WLAN connection can interrupt communication between PIWIS Tester III and the vehicle communication module (VCI). As a result, control unit programming may be aborted.
→ During control unit programming, always connect PIWIS Tester II to the vehicle communication module (VCI) via the USB cable.
- If the driver's key is not recognized in vehicles with Porsche Entry & Drive, programming cannot be started or will be interrupted.
→ Switch on the ignition using the original driver's key. To do this, replace the control unit in the ignition lock with the original driver's key if necessary.
- Carry out general preliminary work for control unit programming as described in → 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER
.
Information
Before doing any other work, the software version must be read out of the air-conditioning control unit using the PIWIS Tester.
→ If the software version is higher than "1040", the remedial action described below must not be carried out .
→ The software in the air-conditioning control unit is already the latest version in this case. Programming the air-conditioning control unit using the programming code will not resolve the problem.
Re-program control unit for air-conditioning system .
The basic procedure for programming a control unit is described in the service information → WM 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER .
Specific information on control unit programming during this repair measure:
Reading out the software version: 'Air-conditioning' control unit → 'Extended identifications' menu
→ Software version:- The measure described below must only be carried out if the software version is lower than 1040 .
Required PIWIS Tester III software version: 33.800.020 (or higher) Type of control unit programming: Control unit programming using the "Campaign" function in the Additional menu on the PIWIS Tester by entering a programming code. Programming code: R4K5P Programming sequence: Read and follow the information and instructions on the PIWIS Tester during the guided programming sequence. The control unit for the air-conditioning system is re-programmed first during the programming sequence. Once programming is complete, the control unit is re-coded automatically .
Do not interrupt programming and coding .Time required for programming and coding: approx. 4 minutes Software version programmed during this repair measure: 1040
Following control unit programming, the software version can be read out of the air-conditioning system control unit in the → 'Extended identification' menu using the PIWIS Tester.Procedure in the event of error messages appearing during the programming sequence: → 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER . Procedure in the event of abnormal termination of control unit programming: Repeat control unit programming by entering the programming code again. Subsequent work:
- Carry out general subsequent work for control unit programming as described in the service information → 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER
.
Invoicing:
The work involved is invoiced under the labor operation:
87022580 Programming air conditioning control - For invoicing and documentation using PQIS, enter the following coding:
87020 Air conditioning control 9830 Cannot establish cause, software re-installed References:
→ 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER
→ 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER