Diagnosis Procedure
Automatic back door open/close function does not operate using all switches.
- CHECK DTC WITH AUTOMATIC BACK DOOR CONTROL MODULE
Check that DTC is not detected with automatic back door control module.
Is the inspection result normal?
YES
GO TO 2.
NO
Perform trouble diagnosis relevant to DTC indicated.
- CHECK BACK DOOR AUTO CLOSURE FUNCTION
Check back door auto closure function.
Is the inspection result normal?
YES
GO TO 3.
NO
Refer to Diagnosis Procedure .
- CHECK POWER SUPPLY AND GROUND CIRCUIT
Check automatic back door control module power supply and ground circuit.
Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace the malfunctioning parts.
- CHECK GROUND CIRCUIT
Check automatic back door control module ground circuit.
Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace the malfunctioning parts.
- CHECK TOUCH SENSOR LH
Check touch sensor LH.
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace the malfunctioning parts.
- CHECK TOUCH SENSOR RH
Check touch sensor RH.
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace the malfunctioning parts.
- REPLACE AUTOMATIC BACK DOOR CONTROL MODULE
- Replace automatic back door control module. Refer to Removal and Installation .
- Confirm the operation after replacement.
Is the result normal?
YES
Inspection End.
NO
Check intermittent incident. Refer to Intermittent Incident .