Diagnosis Procedure
- CHECK FOR FOREIGN MATERIALS IN BACK DOOR LOCK ASSEMBLY
Check for entry of foreign materials in back door lock assembly.
Is the inspection result normal?
YES
GO TO 2.
NO
Remove foreign materials.
- CHECK BACK DOOR OPEN/CLOSE OPERATION
Manually check open and close operation of back door.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace the malfunctioning parts.
- CHECK MONITOR ITEM
- Select AUTOMATIC BACK DOOR CONTROL MODULE using CONSULT.
- Select HALF LATCH SW, OPEN SW and CLOSE SW in DATA MONITOR mode.
- Check that the function operates normally according to the following conditions.
Monitor item
Condition
Status
HALF LATCH SW
Back door
Fully closed/Open
OFF
Half latch
ON
OPEN SW
Fully closed/Half latch
OFF
Open
ON
CLOSE SW
Open/Half latch
OFF
Fully closed
ON
Is the inspection result normal?
YES
GO TO 8.
NO
GO TO 4.
- CHECK SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect back door lock assembly connector.
- Check voltage between back door lock assembly harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Back door lock assembly
Connector
Terminal
D557
4
Ground
Battery voltage
5
6
Is the inspection result normal?
YES
GO TO 6.
NO
GO TO 5.
- CHECK SWITCH CIRCUIT
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and back door lock assembly harness connector.
Automatic back door control module
Back door lock assembly
Continuity
Connector
Terminal
Connector
Terminal
B55
3
D557
6
Yes
5
5
11
4
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
3
No
5
11
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
Back door lock assembly
Ground
Continuity
Connector
Terminal
D557
8
Yes
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace back door lock assembly ground circuit.
- CHECK SWITCH
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 8.
NO
Replace back door lock assembly. Refer to Removal and Installation .
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Inspection End.