Caravan Control Unit Parameters Of Analog Outputs, Function - GF54.21-D-5026TSA
Model 907
with code JA3 (Intelligent body control.)
General
Analog outputs are used to set voltage values to, for example, control a device that executes corresponding actions depending on the voltage applied to its input.
The MB Advanced Control control unit (N175) can operate 5 analog outputs.
Parameters, analog outputs
The analog outputs can switch a maximum of 10 V and a minimum of 250 mV.
The analog outputs have a resolution of 100 mV and a tolerance of 200 mV.
The analog outputs can supply a maximum of 2 mA.
The load on the analog outputs must be greater than 5 kOhm.
As soon as the read voltage value does not match the output voltage, the MBAC switches off the analog output and creates an internal fault entry.
| Caravan control unit configuration of analog outputs, function | GF54.21-D-5021TSA |
| Caravan control unit configuration of analog inputs, function | GF54.21-D-5022TSA |
| Caravan control unit configuration of digital outputs, function | GF54.21-D-5023TSA |
| Caravan control unit configuration of digital inputs, function | GF54.21-D-5024TSA |
| Caravan control unit parameters of analog inputs, function | GF54.21-D-5025TSA |
| Caravan control unit parameters of digital inputs, function | GF54.21-D-5027TSA |
| Caravan control unit parameters of digital outputs, function | GF54.21-D-5028TSA |
| Overview of system components of caravan control unit | GF54.21-D-9992TSA |