Caravan Control Unit Configuration Of Analog Inputs, Function - GF54.21-D-5022TSA
Model 907
with code JA3 (Intelligent body control.)
General
Analog inputs are used to, e.g. read out the values of a sensor and to recognize any voltage thresholds.
The MB Advanced Control control unit (N175) can operate up to 17 analog inputs.
The MBAC consists of two stages, MBAC Stage I and MBAC Stage II.
The MBAC is designed to enable configuration of the assignment of the I/O interfaces. The assignment of the I/O interfaces is configured by the body manufacturer.
An example configuration for the assignment of the I/O interfaces with analog inputs is given below.
Assignment of I/O interfaces with analog inputs (example)
Each stage has exactly one analog input "AI_Battery_Voltage".
Each stage has exactly one analog input "AI_Current_Flow_Difference".
Each stage has exactly one analog input "AI_HeatingJnterior_TempSensor".
Each stage has exactly one analog input "AI_Heating_Wet_Area_TempSensor".
Each stage has exactly one analog input "AI_Heating_Floor_TempSensor".
Each stage has exactly one analog input "AI_HeatingJnlet_TempSensor".
Each stage has exactly one analog input "AI_Heating_Outside1_TempSensor".
Each stage has exactly one analog input "AI_Heating_Outside2_TempSensor".
Each stage has exactly one analog input "AI_Hot_Water_TempSensor".
Each stage has exactly one analog input "AI_Fill_Level_Sensor_Fresh_Water".
Each stage has exactly one analog input "AI_Fill_Level_Sensor_Waste_Water".
Each stage has exactly one analog input "AI_Fill_Level_Sensor_Black".
Each stage has exactly one analog input "AI_Refrigerator_Box_TempSensor".
Each stage has exactly one analog input "AI_Awning_Pushbutton_Switch".
Each stage has exactly one analog input "AI_Rain_Sensor".
| Caravan control unit configuration of analog outputs, function | GF54.21-D-5021TSA |
| Caravan control unit configuration of digital outputs, function | GF54.21-D-5023TSA |
| Caravan control unit configuration of digital inputs, function | GF54.21-D-5024TSA |
| Caravan control unit parameters of analog inputs, function | GF54.21-D-5025TSA |
| Caravan control unit parameters of analog outputs, function | GF54.21-D-5026TSA |
| Caravan control unit parameters of digital inputs, function | GF54.21-D-5027TSA |
| Caravan control unit parameters of digital outputs, function | GF54.21-D-5028TSA |
| Overview of system components of caravan control unit | GF54.21-D-9992TSA |