Diagnostic Procedure
DTC B1313:12 (ELECTRICAL SUPPLY UNIT) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT MAP LIGHT
|
Yes | Go to the next step. |
| No | Replace the map light bulb or map light, then go to Step 5. (See MAP LIGHT BULB REMOVAL/INSTALLATION .) (See MAP LIGHT REMOVAL/INSTALLATION .) |
||
| 2 | INSPECT MAP LIGHT CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 5. | ||
| 3 | INSPECT ELECTRICAL SUPPLY UNIT (ESU) CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 5. | ||
| 4 | INSPECT MAP LIGHT CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between map light terminal B and electrical supply unit (ESU) terminal 2L. If there is a common connector:
Go to the next step. |
||
| 5 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
Go to the next step. |
| No | Go to the next step. | ||
| 6 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [ELECTRICAL SUPPLY UNIT (ESU)] .) |
| No | DTC troubleshooting completed. | ||