Pinpoint Test N : The Fuel Filler Door Lock Is Inoperative
- Refer to REMOTE KEYLESS ENTRY AND ALARM
for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Handles, Locks, Latches and Entry Systems - System Operation and Component Description .
Possible Sources
- Wiring, terminals or connectors
- Fuel filler door latch
- BCM
- NOTE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- N1 CHECK THE DRIVER DOOR LOCK OPERATION
- Ignition OFF.
- Press the lock and unlock buttons on a valid programmed RKE transmitter while observing the driver door lock operation.
Does the driver door lock operate correctly?
Yes GO to N2 No GO to Pinpoint Test K - N2 CHECK THE FUEL FILLER DOOR LOCK CIRCUIT FOR AN OPENNOTE: The following step uses a test lamp to simulate normal circuit loads. Use only a Rotunda Test Lamp (SGT27000) or 250-300mA incandescent bulb test lamp. To avoid connector terminal damage, use the Rotunda Flex Probe kit for the test lamp probe connection to the vehicle. Do not use the test lamp probe directly on any connector.
- Disconnect: Fuel Filler Door Lock C409.
- Connect:
Positive Lead Measurement / Action Negative Lead C409-1 Ground
-
NOTE: The BCM only supplies voltage to the actuator momentarily. It is important to monitor the test lamp while pressing the door lock control switch.
While pressing the door lock control switch in the lock position, monitor the test lamp.
Does the test lamp momentarily illuminate?
Yes GO to N3 No REPAIR the circuit - N3 CHECK THE FUEL FILLER DOOR UNLOCK CIRCUIT FOR AN OPENNOTE: The following step uses a test lamp to simulate normal circuit loads. Use only a Rotunda Test Lamp (SGT27000) or 250-300mA incandescent bulb test lamp. To avoid connector terminal damage, use the Rotunda Flex Probe kit for the test lamp probe connection to the vehicle. Do not use the test lamp probe directly on any connector.
- Connect:
Positive Lead Measurement / Action Negative Lead C409-2 Ground
-
NOTE: The BCM only supplies voltage to the actuator momentarily. It is important to monitor the test lamp while pressing the door lock control switch.
While pressing the door lock control switch in the unlock position, monitor the test lamp.
Does the test lamp momentarily illuminate?
Yes GO to N4 No REPAIR the circuit - Connect:
- N4 CHECK THE FUEL FILLER DOOR LOCK/UNLOCK CIRCUITS FOR CONTINUITYNOTE: The following step uses a test lamp to simulate normal circuit loads. Use only a Rotunda Test Lamp (SGT27000) or 250-300mA incandescent bulb test lamp. To avoid connector terminal damage, use the Rotunda Flex Probe kit for the test lamp probe connection to the vehicle. Do not use the test lamp probe directly on any connector.
-
NOTE: The BCM only supplies voltage to the actuator momentarily. It is important to monitor the test lamp while pressing the door lock control switch.
While pressing the door lock control switch in the unlock position, monitor the test lamp.
Does the test lamp momentarily illuminate?
Yes INSTALL a new fuel filler door lock. REFER to: Fuel Filler Door Assembly . No GO to N5 -
- N5 CHECK THE BCM (BODY CONTROL MODULE) RELAY GROUND CIRCUIT FOR AN OPEN
- Disconnect: BCM C2280F.
- Measure:
Positive Lead Measurement / Action Negative Lead C2280F-63 Ground
Is the resistance less than 3 ohms?
Yes GO to N6 No REPAIR the circuit. - N6 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION
- Disconnect and inspect all the BCM connectors.
- Repair:
- corrosion (install new connectors or terminals - clean module pins)
- damaged or bent pins - install new terminals pins
- pushed-out pins - install new pins as necessary
- Reconnect the BCM connectors and make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM, or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, Refer to BCM GUIDED ROUTINE TESTING No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.