Checking Components And Cables
Check passenger compartment temperature sensor resistance. For resistance values, refer to ECC Electrical Specifications .
Check cable between ECC control module #B6 and passenger compartment temperature sensor terminal 5 for an open-circuit according to Open-Circuit, Permanent Faults and a short-circuit to supply voltage according to Short-Circuit To Supply Voltage. Permanent Faults .
Check cable between ECC control module #B10 and passenger compartment temperature sensor terminal 3 for an open-circuit according to Open-Circuit, Permanent Faults and a short-circuit to supply voltage according to Short-Circuit To Supply Voltage. Permanent Faults .
HINT: A short-circuit on the ground lead can be caused by a short-circuit to supply voltage. Always check ground lead as well for this fault cause.
Remedy as necessary.
Other information:
- To access/replace the passenger compartment temperature sensor, refer to Replacing Passenger Compartment Temperature Sensor (ECC) .
- To connect the breakout box, see Connection Of Breakout Box ECC .
- The voltage on the signal cable varies with temperature. At 20°C voltage should be approximately 2.5 V. For other values, see Signal Specification ECC .
- Continue
Refer to Verification