Stop Light Switch: Installation
- INSTALL STOP LIGHT SWITCH ASSEMBLY
- Temporarily install the stop light switch assembly with the stop light switch lock nut.
- Turn the stop light switch assembly so that the clearance between the nut end and stop light switch cushion is between 0.5 to 2.4 mm (0.020 to 0.095 in.).
- Tighten the stop light switch lock nut.
Torque: 17 N*m (173 kgf*cm, 12 ft.*lbf)
- Connect the connector.
- INSTALL LOWER INSTRUMENT PANEL FINISH PANEL SUB-ASSEMBLY (for Manual Air Conditioning System) (See INSTALLATION )
- INSTALL LOWER INSTRUMENT PANEL FINISH PANEL SUB-ASSEMBLY (for Automatic Air Conditioning System) (See INSTALLATION )
- INSTALL COWL SIDE TRIM SUB-ASSEMBLY LH (See INSTALLATION )
- INSTALL FRONT DOOR SCUFF PLATE LH (See INSTALLATION )