Hand-held tester:
WARNING: This page is about a different variant/trim than selected.
- READ VALUE OF HAND-HELD TESTER (STA SIGNAL)
- Connect the hand-held tester to the DLC3.
- Turn ON the ignition switch. Push the hand-held tester main switch.
- On the hand-held tester, enter the following menus: DIAGNOSIS/ENHANCED OBD II/DATA LIST/ALL/STARTER SIG. Read the values.
Result:
STA SIGNAL RESULTIgnition Switch Condition ON START STA signal OFF ON
- OK: REPLACE ECM (See REPLACEMENT )
- NG: GO TO NEXT STEP.
- INSPECT PARK/NEUTRAL POSITION SWITCH ASSY (See DTC P0705 TRANSMISSION RANGE SENSOR CIRCUIT MALFUNCTION (PRNDL INPUT)
)
OK:
When shift lever is in the N position, the PNP switch is ON.
When shift lever is in the P position, the PNP switch is OFF.
- NG: REPLACE PARK/NEUTRAL POSITION SWITCH ASSY (See REPLACEMENT ) (Go to step 3 AFTER REPLACEMENT)
- OK: GO TO NEXT STEP.
- READ VALUE OF HAND-HELD TESTER (STA SIGNAL)
- Connect the hand-held tester to the DLC3.
- Turn ON the ignition switch. Push the hand-held tester main switch.
- On the hand-held tester, enter the following menus: DIAGNOSIS/ENHANCED OBD II/DATA LIST/ALL/STARTER SIG. Read the values.
Result:
STA SIGNAL RESULTIgnition Switch Condition ON START STA signal OFF ON
- OK: SYSTEM OK
- NG: GO TO NEXT STEP.
- INSPECT IGNITION OR STARTER SWITCH ASSY
- Measure the resistance of the ignition switch terminals.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard:
- NG: REPLACE IGNITION OR STARTER SWITCH ASSY (Go to next step 5 AFTER REPLACEMENT)
- OK: GO TO NEXT STEP.
- Measure the resistance of the ignition switch terminals.
- READ VALUE OF HAND-HELD TESTER (STA SIGNAL)
- Connect the hand-held tester to the DLC3.
- Turn ON the ignition switch. Push the hand-held tester main switch.
- On the hand-held tester, enter the following menus: DIAGNOSIS/ENHANCED OBD II/DATA LIST/ALL/STARTER SIG. Read the values.
Result:
STA SIGNAL RESULTIgnition Switch Condition ON START STA Signal OFF ON
- OK: SYSTEM OK
- NG: REPAIR OR REPLACE HARNESS AND CONNECTOR