DTC B14A2: SUNLOAD Sensor Circuit Short-Circuit
DTC detecting condition:
Sunload sensor (auto light sensor) circuit is shorted.
Trouble symptom:
OPERATION is performed as no sunload.
- Check all DTCs, and if diagnostic code B1244 (light sensor) is output simultaneously, the auto light sensor power supply may be abnormal.
- When the sunload sensor check is performed indoors or in the shade, it could be diagnosed as having an open circuit. Always check the sunload sensor in direct sunlight.
Wiring diagram:
Air conditioning system Ref. to WIRING SYSTEM>AIR CONDITIONING SYSTEM>WIRING DIAGRAM .
- CHECK CONNECTOR
.
- Turn the ignition switch to OFF.
- Check connecting condition of the A/C control panel connector and sunload sensor connector.
Is the check result OK?
Yes: Go to 2.
No: Repair the connector.
- CHECK DTC
.
- Turn the ignition switch to ON.
- Read the DTC of [Air Conditioner] using the Subaru Select Monitor. Ref. to AIR CONDITIONER (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .
Is DTC B14A2 displayed?
Yes: Go to 3.
No: Even if DTC is displayed, the circuit has returned to a normal condition at this time.
Reproduce the failure, and then perform the diagnosis.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause. - CHECK HARNESS (SHORT CIRCUIT)
.
- Turn the ignition switch to OFF.
- Disconnect the connector from the A/C control panel. Ref. to AIR CONDITIONER>CONTROL PANEL>REMOVAL .
- Using a tester, measure the resistance between the A/C control panel connector and chassis ground.
Connector & terminal
(i130) No. 15 - Chassis ground:
Is the resistance 10 kΩ or more?
Yes: Go to 4.
No: Repair or replace the short circuit of the harness.
- CHECK HARNESS
.
- Connect the disconnected connectors.
- Turn the ignition switch to ON.
- Using a tester, measure the voltage between terminals in sunload sensor connector.
Connector & terminal
(i159) No. 1 (+) - (i159) No. 6 (-):
Is the value 0.2 V - 4.8 V when the sensor is exposed to sunlight or inspection light (the voltage varies depending on the light strength), or less than 0.2 V when the sensor is not exposed to direct sunlight (the sensor is covered with a cloth)?
NOTE: The sensor may not respond to weak sunlight or inspection light. If the sensor does not respond, use an incandescent light to take measurements by emitting light at a distance of about 30 cm.Yes: Replace the A/C control panel. Ref. to AIR CONDITIONER>CONTROL PANEL .
No: Replace the sunload sensor. Ref. to LIGHTING SYSTEM>LIGHT CONTROL SENSOR>REMOVAL .