LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2020 >> Crosstrek Base, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (HVAC System (Heater, Ventilator And A/C) (HEV)) >> Refrigerant Pressure with Manifold Gauge Set >> Inspection >> Low-Pressure Side Is Low

Low-Pressure Side Is Low

WARNING: This page is about a different variant/trim than selected.
  1. CHECK REFRIGERANT LEAKS  .

    Check the refrigerant for leaks. Ref. to AIR CONDITIONER (HEV)>REFRIGERANT LEAK CHECK>INSPECTION .

    NOTE: When high-pressure side is less than 0.69 MPa: Go to step 2.

    Are there refrigerant leaks?

    Yes  : Repair the refrigerant leaking points.

    No  : Go to  2.

  2. FILL PROPER AMOUNT OF REFRIGERANT  .

    Drain all refrigerant, and refill proper amount of refrigerant.

    Is refrigerant pressure within the standard value?

    Yes  : Refrigerant pressure is normal.

    No  : Go to  3.

  3. REPLACE THE EXPANSION VALVE - COOLER ASSEMBLY  .

    Replace the expansion valve - cooler assembly. Ref. to AIR CONDITIONER (HEV)>EXPANSION VALVE>REMOVAL>COOLER VALVE .

    Is refrigerant pressure within the standard value?

    Yes  : Refrigerant pressure is normal.

    No  : Check the electric compressor. Ref. to AIR CONDITIONER (DIAGNOSTICS) (HEV)>DIAGNOSTICS WITH PHENOMENON>INSPECTION>COLD AIR DOES NOT COME OUT EVEN WHEN THE A/C SWITCH IS PRESSED. THE GLASS CANNOT BE DEFOGGED. (COMPRESSOR DOES NOT OPERATE (ELECTRIC)) .