Refrigerant Leak Check: Inspection
WARNING: This page is about a different variant/trim than selected.
- Check the refrigerant gas pressure. Ref. to AIR CONDITIONER (HEV)>REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET>PROCEDURE>CHECK REFRIGERANT GAS PRESSURE .
Preparation tool:
Manifold gauge set
- Attach the manifold gauge set.
- Turn READY ON, operate the A/C system for approx. 10 minutes, and check that the high-pressure side indicates 0.69 MPa (7 kgf/cm2 , 100 psi) or more.
- Turn READY OFF and start the leak test.
Preparation tool:
Electronic leak detector (leak tester)
| Items | Condition | Corrective action |
|---|---|---|
| Pipe | Check the connection between the pipe and air conditioner unit. | Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Check the connection between pipe and pressure sensor. | Replace the pressure sensor. | |
| Check the connection between pipe and hose. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the connection between pipe and valve. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the valve and cap in the service port. | Check the rubber seal of the valve and cap. If necessary, replace valve or cap. | |
| Condenser | Check the welded part of condenser and core. | Replace the condenser. |
| Check the connection between valve and condenser. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the connection between pipe and condenser. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Hose | Check the connection between hose and compressor. | Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Check the connection between hose and pipe. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the connection between hose and valve. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the connection between hose and air conditioner unit. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the connection between hose and accumulator. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the rubber part of the flexible hose and pipe seam.
CAUTION:
Carefully check the external surface of flexible hoses and pipes at approx. 25 mm (0.98 in) per second.
|
Replace the hose. | |
| Check the valve and cap in the service port. | Check the rubber seal of the valve and cap. If necessary, replace valve or cap. | |
| Expansion valve | Check the connection between pipe and expansion valve. | Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Check the connection between hose and expansion valve. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the connection between condenser and expansion valve. | Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Check the rubber part of the flexible hose and pipe seam.
CAUTION:
Carefully check the external surface of flexible hoses and pipes at approx. 25 mm (0.98 in) per second.
|
Check the O-ring at connection and tightening torque. If necessary, replace each part. | |
| Evaporator | Remove the drain hose from the heater case, and check the end part for 10 seconds or more. | Replace the evaporator. |
| Check the air vent grille.
NOTE:
Turn the ignition switch to ON, and run the blower at high speed for approx. 1 minute. Stop the blower to check the air vent grille on the instrument panel. While moving the tester closer to the grille, run the blower for 1 or 2 seconds, then stop it. Check the grille at that position for at least 10 seconds.
|
Replace the evaporator. |