DTC B1500: Fuel Sender Open/Short-Circuit Detection
DTC detecting condition:
The fuel gauge circuit is open or shorted.
Trouble symptom:
- Defective fuel gauge.
- Fuel level warning light blinks.
Wiring diagram:
Fuel gauge system Ref. to WIRING DIAGRAM , Fuel Gauge System.
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK DTC
. Read the DTC of the combination meter using the Subaru Select Monitor. Ref. to READ DIAGNOSTIC TROUBLE CODE (DTC) . |
Is DTC B1500 a current malfunction? | Go to step 2 . | Go to step 7 . |
2 CHECK COMBINATION METER
.
|
Is the operation of combination meter OK? | Go to step 3 . | Replace the combination meter. Ref. to Combination Meter . |
3 CHECK HARNESS (OPEN CIRCUIT)
.
Connector & terminal (i10) No. 25 - (R59) No. 1: (i10) No. 37 - (R58) No. 2: (R58) No. 1 - (R59) No. 2: |
Is the resistance 10 Ω or less? | Go to step 4 . | Repair the open circuit of harness or replace harness. |
| 4 CHECK HARNESS (GROUND SHORT CIRCUIT)
. Using the tester, measure the resistance between terminals. Connector & terminal (i10) No. 25 - Chassis ground: (i10) No. 37 - Chassis ground: |
Is the resistance 10 Ω or less? | Repair the short circuit of harness or replace harness. | Go to step 5 . |
| 5 CHECK FUEL SUB LEVEL SENSOR
. Check the fuel sub level sensor as a single part. Ref. to INSPECTION , Fuel Sub Level Sensor. |
Is the sensor normal? | Go to step 6 . | Replace the sensor. Ref. to INSPECTION , Fuel Sub Level Sensor. |
| 6 CHECK FUEL LEVEL SENSOR
. Check the fuel level sensor as a single part. Ref. to INSPECTION , Fuel Level Sensor. |
Is the sensor normal? | Go to step 7 . | Replace the sensor. Ref. to INSPECTION , Fuel Level Sensor. |
7 CHECK CONNECTOR
.
|
Is there poor contact of connector? | Repair or replace the poor contact of connector. | Go to step 8 . |
| 8 CHECK CURRENT DATA
. Using the Subaru Select Monitor, display «Fuel level resistance» from «Data monitor». Ref. to READ CURRENT DATA . |
Does the data display 10 - 570 Ω? | Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|
Replace the combination meter. Ref. to Combination Meter . |