Low-Pressure Side Is High

DIAGNOSTIC PROCEDURE

Step Check Yes No
1 FILL PROPER AMOUNT OF REFRIGERANT. 
Drain the refrigerant completely, and then refill the proper amount of refrigerant.
  • Recovery: < Ref. to PROCEDURE , Refrigerant Recovery Procedure. >
  • Refill: < Ref. to PROCEDURE , Refrigerant Charging Procedure. >
Is the refrigerant pressure within the specified range? Refrigerant pressure is normal. Go to step 2. 
2 REPLACE EXPANSION VALVE. 
Replace the expansion valve. < Ref. to REMOVAL , Expansion Valve. >
Is the refrigerant pressure within the specified range? Refrigerant pressure is normal. Replace the evaporator. < Ref. to REMOVAL , Evaporator. >