Combination Meter System: Inspection: Self-Diagnosis
The self-diagnosis (checking of each meter, warning light, indicator, illumination, LCD, buzzer sound) of combination meter can be performed in the following procedure.
- Within 3 seconds after turning the ignition switch to ON, set the lighting switch to tail light or headlight position.
- Press the ODO/trip meter knob three times.
- Turn the lighting switch to OFF, and press the ODO/trip meter knob three times.
- Set the lighting switch to tail light or headlight position again, and press the ODO/trip meter knob three times.NOTE:
- When pressing the ODO/trip meter knob four times, the display changes to DTC display mode. Refer to DTC DISPLAY MODE , INSPECTION, Combination Meter System.
- When the self-diagnosis function operates, the warning light, indicator, and LCD display checks are performed. After this, operation checks are performed in the order of meter, illumination, and buzzer for each press of the ODO/trip meter knob button. Refer to LIST OF SELF-DIAGNOSIS MODE OPERATION , INSPECTION, Combination Meter System. Turn the ignition switch to OFF to cancel the self-diagnosis function.
- When the engine starts during diagnosis, the self-diagnosis function is not cancelled, however, once the vehicle starts driving, the self-diagnosis function is deactivated automatically for safety.