Check condition of battery - AR54.10-P-1129CW
WARNING: This page does not describe the selected car, but rather 33 other vehicles, including the 2016 Mercedes-Benz E63 S AMG, 2016 Mercedes-Benz E400, 2016 Mercedes-Benz E350, 2016 Mercedes-Benz E300, and 2016 Mercedes-Benz E250. However, it is still accessible from the selected car via links, so may be relevant.
MODEL 197 without CODE P98 (Black Series)
MODEL 204, 207, 212, 218
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Remove | |||
| 1 | Expose on-board electrical system battery | ||
| Check | |||
| 2 | Visual inspection for external leaks | In the event of leaks: ↓ Replace on-board electrical system battery |
|
| MODEL 207, 212, 218 | AR54.10-P-0005EW | ||
| MODEL 204.0/2/3/9 | AR54.10-P-0005CW | ||
| MODEL 197 without CODE P98 (Black Series) |
AR54.10-P-0005RQ | ||
| 3.1 | Check fluid level in on-board electrical system battery, refill with distilled water if necessary | Without service fill level indicator, not on absorbent glass mat battery. | |
| 3.2 | Check fluid level of on-board electrical system battery | With service fill level indicator, not on absorbent glass mat battery Check fluid level using service fill level indicator, if color is white then the acid level is too low: Replace on-board electrical system battery |
|
| MODEL 207, 212, 218 | AR54.10-P-0005EW | ||
| MODEL 204.0/2/3/9 | AR54.10-P-0005CW | ||
| MODEL 197 without CODE P98 (Black Series) |
AR54.10-P-0005RQ | ||
| 4 | Check on-board electrical system battery | AR54.10-P-1129-01A | |
| Battery capacity 60 Ah VRLA | *BE54.10-P-1006-01A | ||
| Battery capacity 60 Ah | *BE54.10-P-1007-01A | ||
| Battery capacity 61 Ah | *BE54.10-P-1008-01A | ||
| Battery capacity 62 Ah | *BE54.10-P-1009-01A | ||
| Battery capacity 70 Ah VRLA | *BE54.10-P-1010-01A | ||
| Battery capacity 74 Ah | *BE54.10-P-1011-01A | ||
| Battery capacity 80 Ah VRLA | *BE54.10-P-1012-01A | ||
| Battery capacity 84 Ah | *BE54.10-P-1013-01A | ||
| Battery capacity 95 Ah VRLA Battery tester |
*BE54.10-P-1015-01A | ||
| 5 | Reduce increased voltage after charging process | with an on-board electrical system battery, which is disconnected from the on-board electrical system, the message "surface voltage detected" in the display of the Midtronics battery test/test equipment. | |
| AR54.10-P-1129-03A | |||
Stress tester |
|||
| 6 | Charge on-board electrical system battery | With the test code "Charge and check" on the Midtronics battery tester. | |
| AR54.10-P-1130CW | |||
| Install | |||
| 7 | Install remaining parts |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA | Cold cranking amps | As per EN | A | 680 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1007-01A | Battery capacity 60 Ah | Cold cranking amps | As per EN | A | 510 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1008-01A | Battery capacity 61 Ah | Cold cranking amps | As per EN | A | 540 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20 °C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 190 | |||
| Load time | s | 10 | |||
| Voltage | V | ≈10 | |||
| Cold cranking amps | As per EN | A | 480 | ||
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA | Cold cranking amps | As per EN | A | 760 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1011-01A | Battery capacity 74 Ah | Battery test at 20 °C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 265 | |||
| Load time | s | 10 | |||
| Voltage | V | ≈10 | |||
| Cold cranking amps | As per EN | A | 680 | ||
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1012-01A | Battery capacity 80 Ah VRLA | Cold cranking amps | As per EN | A | 800 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1013-01A | Battery capacity 84 Ah | Cold cranking amps | As per EN | A | 700 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold cranking amps | As per EN | A | 850 |