LEMON Manuals: Even more car manuals for everyone
Home >> Smart >> 2015 >> Fortwo Electric Drive, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 104 (Electrical System, Equipment & Instruments - 212 Chassis - 3 Of 6) >> Testing & Repair >> Check condition of battery - AR54.10-P-1129CW

Check condition of battery - AR54.10-P-1129CW

WARNING: This page does not describe the selected car, but rather 33 other vehicles, including the 2016 Mercedes-Benz E63 S AMG, 2016 Mercedes-Benz E400, 2016 Mercedes-Benz E350, 2016 Mercedes-Benz E300, and 2016 Mercedes-Benz E250. However, it is still accessible from the selected car via links, so may be relevant.

MODEL 197 without CODE P98 (Black Series) 

MODEL 204, 207, 212, 218 

DANGER Risk of explosion  from explosive gas. Risk of poisoning and caustic burns  from swallowing battery electrolyte. Risk of injury  through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A
NOTES Notes on battery   AH54.10-P-0001-01A
REMOVING Remove     
1 Expose on-board electrical system battery    
INSPECT Check     
2 Visual inspection for external leaks In the event of leaks:

Replace on-board electrical system battery
 
MODEL 207, 212, 218 AR54.10-P-0005EW
MODEL 204.0/2/3/9 AR54.10-P-0005CW
MODEL 197
without CODE P98 (Black Series)
AR54.10-P-0005RQ
3.1 Check fluid level in on-board electrical system battery, refill with distilled water if necessary Without service fill level indicator, not on absorbent glass mat battery.  
3.2 Check fluid level of on-board electrical system battery With service fill level indicator, not on absorbent glass mat battery
Check fluid level using service fill level indicator, if color is white then the acid level is too low:
Replace on-board electrical system battery
 
MODEL 207, 212, 218 AR54.10-P-0005EW
MODEL 204.0/2/3/9 AR54.10-P-0005CW
MODEL 197
without CODE P98 (Black Series)
AR54.10-P-0005RQ
4 Check on-board electrical system battery   AR54.10-P-1129-01A 
Battery capacity 60 Ah VRLA *BE54.10-P-1006-01A 
Battery capacity 60 Ah *BE54.10-P-1007-01A 
Battery capacity 61 Ah *BE54.10-P-1008-01A 
Battery capacity 62 Ah *BE54.10-P-1009-01A 
Battery capacity 70 Ah VRLA *BE54.10-P-1010-01A 
Battery capacity 74 Ah *BE54.10-P-1011-01A 
Battery capacity 80 Ah VRLA *BE54.10-P-1012-01A 
Battery capacity 84 Ah *BE54.10-P-1013-01A 
Battery capacity 95 Ah VRLA
Battery tester
*BE54.10-P-1015-01A 
5 Reduce increased voltage after charging process with an on-board electrical system battery, which is disconnected from the on-board electrical system, the message "surface voltage detected" in the display of the Midtronics battery test/test equipment.  
  AR54.10-P-1129-03A 
IMPORTANT Check the on-board electrical system battery again after the increased voltage is reduced.
Stress tester
 
6 Charge on-board electrical system battery With the test code "Charge and check" on the Midtronics battery tester.  
  AR54.10-P-1130CW 
IMPORTANT Check the on-board electrical system battery again after charging.  
INSTALLING Install     
7 Install remaining parts    
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1006-01A Battery capacity 60 Ah VRLA Cold cranking amps As per EN A 680
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1007-01A Battery capacity 60 Ah Cold cranking amps As per EN A 510
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1008-01A Battery capacity 61 Ah Cold cranking amps As per EN A 540
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1009-01A Battery capacity 62 Ah Battery test at 20 °C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 190
Load time s 10
Voltage V ≈10
Cold cranking amps As per EN A 480
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1010-01A Battery capacity 70 Ah VRLA Cold cranking amps As per EN A 760
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1011-01A Battery capacity 74 Ah Battery test at 20 °C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 265
Load time s 10
Voltage V ≈10
Cold cranking amps As per EN A 680
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1012-01A Battery capacity 80 Ah VRLA Cold cranking amps As per EN A 800
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1013-01A Battery capacity 84 Ah Cold cranking amps As per EN A 700
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation MODEL ALL
BE54.10-P-1015-01A Battery capacity 95 Ah VRLA Cold cranking amps As per EN A 850