Hazard Lamps Inoperative
Hazard Lamps Inoperative
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views |
|||
| 1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 | Operate the left and right turn signals. Do the turn signals operate properly? |
Go to Step 4 | Go to Turn Signal Lamps and/or Indicators Inoperative |
| 4 |
|
Go to Step 5 | Go to Step 7 |
| 5 | Connect a 3 amp fused jumper wire between the turn/hazard request circuit of the hazard switch connector and the ground circuit of the hazard switch connector. Do all of the turn signal lamps flash on and off? |
Go to Step 6 | Go to Step 8 |
| 6 | Inspect for poor connections at the harness connector of the hazard switch. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 10 | Go to Step 9 |
| 7 | Repair an open or high resistance in the turn/hazard request circuit between splice 270 and the hazard switch. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 10 | - |
| 8 | Repair an open or high resistance in the ground circuit of the hazard switch. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 10 | - |
| 9 | Replace the hazard switch. Refer to Hazard Warning Switch Replacement . Did you complete the replacement? |
Go to Step 10 | - |
| 10 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |