Inspection Procedure A-13: Power liftgate becomes as door-ajar: Diagnosis
- STEP 1. Using scan tool (M.U.T.-III), read the diagnostic trouble code.
- Operate the power liftgate.
- Check whether a diagnostic trouble code is stored in the power liftgate control unit.
Q: Is the check result normal?
- YES: Go to Step 2.
- NO: Refer to DIAGNOSTIC TROUBLE CODE CHART .
- STEP 2. Using scan tool (M.U.T.-III), check data list.
Check the signals related to the power liftgate operation.
CAUTION: To prevent damage to scan tool (M.U.T.-III), always turn the power supply mode of the engine switch to the OFF position before connecting or disconnecting scan tool (M.U.T.-III).- Connect scan tool (M.U.T.-III). Refer to HOW TO CONNECT THE SCAN TOOL (M.U.T.-III)
- Turn the power supply mode of the engine switch to OFF.
- Check the ETACS data list.
- Liftgate lock release handle: OFF → ON
- Half latch switch: OFF → ON
- Full latch switch: OFF → ON
- Door-ajar switch: OFF → ON
- Neutral switch: OFF → ON
- Liftgate sensor LH: OFF → ON
- Liftgate sensor RH: OFF → ON
Item No. Item name Normal conditions Item 3 Gate handle SW OFF → ON Item 5 Half-latch SW OFF → ON Item 6 Full-latch SW OFF → ON Item 7 Half door switch OFF → ON Item 8 Neutral SW OFF → ON Item 9 Touch sensor (left) OFF → ON Item 10 Touch sensor (right) OFF → ON OK: Normal conditions are displayed for all the items.
Q: Is the check result normal?
All are normal.: When the liftgate lock release handle is operated manually, and if the liftgate is left as is without being opened, a door-ajar status may occur. Therefore, be sure not to leave the liftgate in the middle of operation. Go to Step 3.
Normal condition is not displayed for item No. 3.: Refer to INSPECTION PROCEDURE B-3 "LIFTGATE LOCK RELEASE HANDLE SIGNAL IS NOT RECEIVED" .
Normal condition is not displayed for item 5 and 6.: Refer to INSPECTION PROCEDURE B-6 "HALF LATCH SWITCH AND/OR FULL LATCH SWITCH SIGNALS ARE NOT RECEIVED" .
Normal condition is not displayed for item No. 7.: Refer to INSPECTION PROCEDURE B-4 "DOOR-AJAR SWITCH SIGNAL IS NOT RECEIVED" .
Normal condition is not displayed for item No. 8.: Refer to INSPECTION PROCEDURE B-5 "NEUTRAL SWITCH SIGNAL IS NOT RECEIVED" .
Normal condition is not displayed for item 9 and 10.: Refer to INSPECTION PROCEDURE B-7 "LIFTGATE SENSOR SIGNAL IS NOT RECEIVED" .
- STEP 3. Check of the troubles
Check whether the power liftgate works normally.
Q: Is the check result normal?
- YES: Intermittent malfunction (Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTION ).
- NO: Replace the power liftgate control unit.