54 10 240 Removing and installing/replacing front glass lid
WARNING: This page is about a different variant/trim than selected.
Installation:
- Microencapsulated screws (Loctite) must be replaced and may not be reused
- Screw connection must be completed within 20 mins. (start of curing)
- Microencapsulated screws must not be retightened
- Clean thread of nut beforehand in event of repeated use
Release left and right screws (1).
Tightening torque 54 12 4AZ .
Carefully lift out glass lid.
Installation:
Replace Torx screw.
Adjust glass lid .