Home >> Mercedes Benz >> 2019 >> S450 Base >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Electric Motor Systems >> Electrical Drive System - 222 Chassis >> Basic Knowledge >> Automatic Engine Stop, Function - GF08.30-P-3001LFH

Automatic Engine Stop, Function - GF08.30-P-3001LFH

Engine 276 in model 222.057/157 

Engine 276 in model 222.163 

Engine 276 in model 222.173 

Engine 651.9 in model 222.004/104 

IMPORTANT The subfunction "automatic engine stop function" is considered and described from the point of view of the hybrid drive system.

Information about the subfunction "Start/stop energy management, function" for the 12 V on-board electrical system is documented in the associated function.

Information about the subfunction "Engine management start/stop, function" from the combustion engine management perspective is documented in the associated function.

Function requirements for an automatic engine stop - general points 

IMPORTANT The automatic engine stop in hybrid vehicles is equivalent to electrical driving.

Automatic engine stop - general points 

An automatic engine stop is initiated if this is meaningful as part of the system optimization and the requested drive torque can be generated purely electrically. For automatic engine stop the internal combustion engine is switched off by the CDI control unit (N3/9) (for a diesel engine) or the ME-SFI [ME] control unit (N3/10) (for a gasoline engine) without switching off terminal 15.

The following listed read in signals are just related to the release for the automatic engine stop from external systems such as:

Internal signals from the combustion engine which are read in for automatic engine stop are described in the associated document.

Torque influencing requests and signals to the torque coordinator interface in the CDI or ME-SFI [ME] control unit are described in the associated documents.

The CDI control unit or the ME-SFI [ME] control unit reads in the following signals for release of the automatic engine stop:

IMPORTANT

If the internal combustion engine is off (e.g. automatic engine stop), the oil supply for the A/T is secured over the electrical auxiliary oil pump.

Further information about the oil supply for the automatic transmission is described in the associated document.

IMPORTANT If the internal combustion engine is off (e.g. automatic engine stop), the fuel supply is influenced appropriately over the FSCU (N118).

Further information about the fuel supply during an automatic engine stop is described in the associated document.

IMPORTANT

If the automatic start/stop intervals exceed an established number in a certain time, the automatic engine stop is suppressed for a certain period of time.

Function sequence of an automatic engine stop 

The CDI control unit or the ME-SFI [ME] control unit continuously performs a system diagnosis and assesses the function requirements for an automatic engine stop.

The status of the electric auxiliary oil pump is checked before triggering of the automatic engine stop and then immediately actuated or actuated during triggering of the automatic engine stop by the fully integrated transmission control unit. The electric auxiliary oil pump secures the hydraulic system's oil supply in the automatic transmission when the internal combustion engine is switched off.

The internal combustion engine is switched off by the CDI control unit or the ME-SFI [ME] control unit if certain internal combustion engine conditions are fulfilled and all of the following conditions and releases have been awarded:

The CDI or ME-SFI [ME] control unit requests actuation of the wet clutch or engine separator clutch via the CAN network from the fully integrated transmission control unit in order to disconnect the combustion engine from the powerplant. After receiving feedback that the wet clutch or engine separator clutch is open, the CDI or ME-SFI [ME] control unit shuts off the combustion engine.

If during the automatic engine stop a release is retracted or a prerequisite is no longer fulfilled, the internal combustion engine will automatically be started without any defined action on the part of the driver.

Further information concerning actuation of the wet clutch or engine separator clutch is available in the associated documents.

If during the automatic engine stop a release is retracted or a prerequisite is no longer fulfilled, the internal combustion engine will automatically be started without any defined action on the part of the driver.