Automatic Engine Stop, Function - GF08.30-P-3001LFH
Engine 276 in model 222.057/157
Engine 276 in model 222.163
Engine 276 in model 222.173
Engine 651.9 in model 222.004/104
The subfunction "automatic engine stop function" is considered and described from the point of view of the hybrid drive system.
Information about the subfunction "Start/stop energy management, function" for the 12 V on-board electrical system is documented in the associated function.
Information about the subfunction "Engine management start/stop, function" from the combustion engine management perspective is documented in the associated function.
Function requirements for an automatic engine stop - general points
- Hybrid drive system "READY"
- Engine runs
- System diagnosis complete and fault-free
- Engine hood closed
- No Crash event occurred in the driving cycle
- Vehicle speed < 160 km/h
- Transmission oil temperature > 0°C
The automatic engine stop in hybrid vehicles is equivalent to electrical driving.
Automatic engine stop - general points
An automatic engine stop is initiated if this is meaningful as part of the system optimization and the requested drive torque can be generated purely electrically. For automatic engine stop the internal combustion engine is switched off by the CDI control unit (N3/9) (for a diesel engine) or the ME-SFI [ME] control unit (N3/10) (for a gasoline engine) without switching off terminal 15.
The following listed read in signals are just related to the release for the automatic engine stop from external systems such as:
- High-voltage on-board electrical system
- V on-board electrical system
- vehicle climate control
- Regenerative braking system
Internal signals from the combustion engine which are read in for automatic engine stop are described in the associated document.
Torque influencing requests and signals to the torque coordinator interface in the CDI or ME-SFI [ME] control unit are described in the associated documents.
The CDI control unit or the ME-SFI [ME] control unit reads in the following signals for release of the automatic engine stop:
- Climate control, control unit (N22/1) via the CAN network:
- A/C status
- Electronic Stability Program control unit (N30/4), via the CAN network:
- Wheel speed
- Engine stop prohibition
- Engine start request
- Battery management system control unit (N82/2) via the CAN network:
- Voltage of high-voltage battery (A100g1)
- Temperature of high-voltage battery
- Power electronics control unit (N129/1) via the CAN network:
- Status of the electrical machine (A79/1)
- Torque of electrical machine
- Rotational speed of electrical machine
- Fully integrated transmission control unit (Y3/8n4) via the CAN network:
- Gear range status
- Status of wet clutch (except model 222.173)
- Status of engine separator clutch (model 222.173)
- Transmission oil temperature
- Status of the electrical auxiliary oil pump (M42)
- Supplemental Restraint System control unit (N2/10)
- Direct crash signal
- Supplemental Restraint System control unit via the CAN network
- Indirect crash signal
- Status of driver seat belt
- Front SAM control unit (N10/6) via the CAN network:
- Engine stop prohibition
- Engine start request
- Signal that engine hood is closed
- Left front door control unit (N69/1) via the CAN network
- Contact switch signal (left front door)
If the internal combustion engine is off (e.g. automatic engine stop), the oil supply for the A/T is secured over the electrical auxiliary oil pump.
Further information about the oil supply for the automatic transmission is described in the associated document.
- Oil supply for automatic transmission, function
If the internal combustion engine is off (e.g. automatic engine stop), the fuel supply is influenced appropriately over the FSCU (N118).
Further information about the fuel supply during an automatic engine stop is described in the associated document.
- Engine timing, start/stop function
If the automatic start/stop intervals exceed an established number in a certain time, the automatic engine stop is suppressed for a certain period of time.
Function sequence of an automatic engine stop
The CDI control unit or the ME-SFI [ME] control unit continuously performs a system diagnosis and assesses the function requirements for an automatic engine stop.
The status of the electric auxiliary oil pump is checked before triggering of the automatic engine stop and then immediately actuated or actuated during triggering of the automatic engine stop by the fully integrated transmission control unit. The electric auxiliary oil pump secures the hydraulic system's oil supply in the automatic transmission when the internal combustion engine is switched off.
The internal combustion engine is switched off by the CDI control unit or the ME-SFI [ME] control unit if certain internal combustion engine conditions are fulfilled and all of the following conditions and releases have been awarded:
- Vehicle speed < 160 km/h
- Transmission oil temperature > 0°C
- gear range plausible
- Adequate vacuum in the brake booster
- Electronic Stability Program has issued approval.
- Engine hood closed
- no crash event
- the condition of the 12-V on-board electrical system is OK and release has been issued
- Charge level of high-voltage battery is sufficient
- oil supply to A/T secured
- Driver door closed
- Driver seat belt applied
- interior temperature can be regulated with the current coolant temperature of the internal combustion engine.
- Climate control, control unit has issued approval.
The CDI or ME-SFI [ME] control unit requests actuation of the wet clutch or engine separator clutch via the CAN network from the fully integrated transmission control unit in order to disconnect the combustion engine from the powerplant. After receiving feedback that the wet clutch or engine separator clutch is open, the CDI or ME-SFI [ME] control unit shuts off the combustion engine.
If during the automatic engine stop a release is retracted or a prerequisite is no longer fulfilled, the internal combustion engine will automatically be started without any defined action on the part of the driver.
Further information concerning actuation of the wet clutch or engine separator clutch is available in the associated documents.
If during the automatic engine stop a release is retracted or a prerequisite is no longer fulfilled, the internal combustion engine will automatically be started without any defined action on the part of the driver.
Further information and descriptions of the automatic engine start can be found in the associated documents.
| Electrical function schematic for automatic engine stop | PE08.30-P-2053-97SEH | ||
| Overview of system components, hybrid drive system | GF08.30-P-9999LFH |