Heating wiper support, function - GF82.30-P-2003CA
MODEL 207.3/4
Function requirements, general
- "Engine running" or "drive train operational" signal on
- Outside temperature T < 5 °C
The CDI control unit (N3/9) (with diesel engine) or the ME-SFI [ME] control unit (N3/10) (with gasoline engine) sends the "Engine running" or "Drivetrain operational" signal over the chassis CAN (CAN E) (up to 31.5.13) or chassis CAN 1 (CAN E1) (as of 1.6.13) to the front SAM control unit with fuse and relay module (N10/1).
The outside temperature is detected by the outside temperature sensor (B14). The front SAM control unit reads in the signal of the outside temperature sensor directly, calculates the actual outside temperature and sends this over the interior CAN (CAN B) to the instrument cluster (A1). The instrument cluster calculates the outside temperature to be displayed, and sends it over the interior CAN to the front SAM control unit.
If the front SAM control unit cannot receive an outside temperature value from the instrument cluster, it calculates the outside temperature itself.
Heated wiper park position, general
Heating the wiper park positions at low outside temperatures prevents the wiper blades from freezing to the windshield.
Heated wiper park position function sequence
The front SAM control unit switches on the wiper park position heater (R2/10) when the engine is running and at an outside temperature of T < 5 °C. This takes into consideration the engine temperature at which the wiper park position heater was switched on. If the weather is currently precipitation free, the maximum operating time is t = 25 min. If the outside temperature rises to a value of T > 15 °C, the front SAM control unit switches off the wiper park position heater. The front SAM control unit reads in all the relevant data and actuates the wiper park position heater accordingly.
The wiper park position heater is switched off automatically under the following conditions:
- No wiper request for t > 25 min. and engine coolant temperature of T < 70 °C
- Engine coolant temperature of T < 70 °C and the sun sensor (B32/3) signals "Solar radiation through the windshield" The sun sensor information is not evaluated until after t = 15 min.
- No wiper request for t > 15 min and engine coolant temperature of T > 70 °C
If a wiper request is then pending, the wiper park position heater is activated again. If the windshield has only been washed, the front SAM control unit then switches off the wiper park position heater after t = 10 min.
- When the vehicle is stationary, the wiper park position heater is switched off after t = 10 minutes
The automatic climate control control and operating unit (N22/7) reads in the data of the sun sensor directly and sends the data via interior CAN to the front SAM control unit.
The wiper request is defined by means of the switch position of the combination switch (S4). The steering column tube module control unit (N80) reads in the switch position of the combination switch directly and sends this over the chassis CAN (up to 31.5.13) or chassis CAN 1 (as of 1.6.13) to the front SAM control unit.
The engine coolant temperature is recorded by the coolant temperature sensor (B11/4). The CDI control unit or the ME-SFI [ME] control unit reads in the signal for the coolant temperature sensor directly, calculates the engine coolant temperature, and sends this over the chassis CAN (up to 31.5.13) or chassis CAN 1 (as of 1.6.13) to the front SAM control unit.
| Electrical function schematic for heated wiper park position | PE82.35-P-2053-97EAA | ||
| Overview of system components, wiper system (WSA) | GF82.30-P-9997CA |