Remove/install steering column adjustment switch - AR54.25-P-2804GS
MODEL 463.244/245/247/248/249/250/254/309/322/323/332/333 as of 1.7.02 up to 31.5.04, 463.243/246 up to 31.5.04
| Remove/install | |||
|---|---|---|---|
| 1 | Move steering into center position | ||
| 2.1 | Activate Service mode in Tele-Aid emergency call system | Only for models 463.243/244/245/247/248/250/254/309/322/323/332/333 with TeleAid - car telephone emergency call system, code ET2 | AR82.95-P-0005-03GR |
| Notes regarding the Tele-Aid emergency call system | AH82.95-P-0001-01GA | ||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Pour battery acid only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 3 | Disconnect battery ground cable | All models 463 except model 463.248 with special protection version code 979 | AR54.10-P-0003G |
| Model 463.248 with special protection version code 979 | AR54.10-P-0003PM | ||
| Notes on battery | All models | AH54.10-P-0001-01A | |
| 4 | Remove steering wheel | AR46.10-P-0100P | |
| 5 | Remove fanfare horns and airbag clock spring contact | AR46.10-P-0200GS | |
| 6 | Remove steering angle sensor (B24/8) | AR46.10-P-0300GS | |
| 7 | Pull the steering column adjustment switch (S59) out of the steering column switch module (2) | ||
| 8 | Install in the reverse order | ||
| 9.1 | Deactivate service mode in TELE AID emergency call system | Only for models 463.243/244/245/247/248/250/254/309/322/323/332/333 with TeleAid - car telephone emergency call system, code ET2 | AR82.95-P-0005-03GR |
| Notes regarding the Tele-Aid emergency call system | AH82.95-P-0001-01GA | ||
| 10 | Activate steering angle sensor (B24/8) | AR46.10-P-0300-01I | |
| 11 | Read out fault memory | ||
| Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04A | ||
| *WH58.30-Z-1048-13A | |||
| 12 | Perform basic programming | AR00.19-P-0200P |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation | |
|---|---|---|
| WH58.30-Z-1048-13A | STAR DIAGNOSIS diagnostic system, Compact Passenger Car | 6511 1801 00 |