LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2008 >> C350 >> Repair and Diagnosis >> Restraints >> Seat Belts >> Seats, Restraint Systems -- Basic Knowledge -- C63/C350 (204) - 1 Of 2 >> Basic Knowledge >> Heated seats (HS) function - GF91.30-P-0003CW

Heated seats (HS) function - GF91.30-P-0003CW

MODEL 204.0 /2 with CODE (873) Heated left and right front seats up to Model Year 8 

General information 

Using the heated seats (HS [SIH]), it is possible to heat the seat cushions and the backrests of the front seats in three heating stages.

Function requirements 

IMPORTANT The circuit status is transmitted to the rear SAM control unit with fuse and relay module (N10/2) by the electronic ignition lock control unit (N73) via the interior CAN.

The SIH enables the following subfunctions: 

Manual on/off function sequence 

Operation takes place via the left front heated seat button (N72/1s10) and the right front heated seat button (N72/1s11) in the upper control panel control unit (N72/1).

Each actuation of a heated seat button is transmitted to the front SAM control unit with fuse and relay module (N10/1) by the upper control panel control unit via the instrument panel LIN. This transmits the request via the interior CAN to the rear SAM control unit with fuse and relay module (N10/2), which then switches the SIH on.

The following heating elements are actuated by the rear SAM control unit:

The heat output depends on the number of the times the relevant heated seat button is pressed:

Press once: Heating stage 3 (100 % heat output)

Press two times: Heating stage 2 (70 % heat output)

Press three times: Heating stage 1 (40 % heat output)

IMPORTANT Pressing the button again switches the SIH off.

Function indicator 

The particular heating stage that is active is indicated via red LEDs in the relevant heated seat button.

Automatic switch off function sequence 

The timer control is realized by the rear SAM control unit.

IMPORTANT The timer settings of the 3 heating stages can be parameterized in the rear SAM control unit using STAR DIAGNOSIS.

Other shutoff criteria:

If circuit 15C remains On, the timer control continues to run for t = 5 min. If circuit 15R is switched on again, then the HS [SIH] are also switched on at the heating stage active according to the timer control.

The current interior temperature value is transmitted to the rear SAM control unit via the interior CAN by the automatic air conditioning control and operating unit (N22/7).

IMPORTANT If no plausible interior temperature value is present, the outside temperature value is used instead.

REFER TO SYSTEM WIRING DIAGRAMS Function diagram, electrical system, heated seats (SIH)   PE91.30-P-2050-99FAA
  Heated seats (SIH) location of components   GF91.30-P-0003-02CW 
  Heated seats (HS) block diagram   GF91.30-P-0003-03CW 
  Front SAM control unit with fuse and relay module, component description N10/1 GF54.21-P-6070CW
  Rear SAM control unit with fuse and relay module, component description N10/2 GF54.21-P-6030CW
  Automatic air conditioning control and operating unit, component description N22/7
Without code (581) Comfort automatic air conditioning
GF83.40-P-3000CWA
with code (581) Comfort automatic air conditioning GF83.40-P-3000CWB
  Upper control panel control unit, component description N72/1 GF54.21-P-6040CW
  Electronic ignition lock control unit, component description N73 GF80.57-P-6001CW