Automatic window closing via recirculated air pushbutton 

The position of the windows prior to the commencement of the closing sequence is stored.

It is kept in memory until circuit 15 is switched off.

If this function is requested again during or after completion of the closing sequence, then the initially stored position is retained.

To minimize relay noise, any window that is already in the upper end stop position will not be activated.

Automatic window opening via recirculated air pushbutton 

The function can be activated if automatic closing via the recirculated air pushbutton was performed beforehand after circuit 15 "ON". The windows open automatically as far as the stored position if the current window position is at least 8 Hall pulses above the stored opening position.

A window will not be activated if it is positioned less than 8 Hall pulses above the stored opening position, or if it has in the meantime been lowered to below the stored position.

If automatic closing via the recirculating air pushbutton is initiated again while the window is opening, but before it has reached its stored position, the opening position initially stored will be retained in memory.

The automatic window closing via recirculating air pushbutton  function will be aborted if

The automatic window opening via recirculating air pushbutton  function will be aborted if

IMPORTANT The window positions stored for the function of convenience closing via the recirculated air pushbutton are erased when the ignition is switched off.

  Convenience opening of power windows function   GF72.29-P-3004PP
  Convenience closing of power windows function   GF72.29-P-3005PP
  Convenience opening of sliding/tilting roof function Model 203.0/203.2 GF77.20-P-2000PP
  Convenience closing of sliding/tilting roof function Model 203.0/203.2 GF77.20-P-2001PP
  Automatically raise/lower power windows function   GF72.29-P-3007PP
  Automatic opening/closing of sliding/tilting roof function Model 203.0/203.2 GF77.20-P-2008PP