Removing and installing the circulation pump for the low temperature water circuit - AR09.41-P-6925GX
ENGINE 113.993 in MODEL 463.270 /271
| Remove/Install | |||
| Risk of injury to skin and eyes suffering scalding from contact with hot coolant spray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage bottles. Wear protective gloves, protective clothing and eye protection. |
AS20.00-Z-0001-01A | |
| 1 | Drain coolant | AR20.00-P-1142GX | |
| 2 | Remove the front engine cover (1) | ||
| 3 | Remove air intake hose (2) | ||
| 4 | Detach the coolant hoses (3, 4) at the charge air cooler circulation pump (M44) | ||
| 5 | Detach the electrical connector (5) at the charge air cooler circulation pump (M44) | ||
| 6 | Remove the heat protection shield (6) | ||
| 7 | Remove charge air cooler circulation pump (M44) | ||
| 8 | Install in the reverse order | ||
| 9 | Pour in coolant | AR20.00-P-1142GX | |
| 10 | Bleed low temperature circuit | AR20.00-P-1145GX |