Synchronizing sliding / pop-up roof, function - GF77.20-P-3002GH
MODEL 163 with CODE (414a) Electric glass sliding/pop-up roof
Synchronization is necessary to match the counter status of the position counter with the actual position of the sliding /pop-up roof in the evaluation electronic module for the sliding /pop-up roof (M12) Synchronization is required when the sliding /pop-up roof (M12) has been disconnected from the power supply or a malfunction has occurred during position measurement resulting in desynchronization .
In the desynchronized state the evaluation electronic module in the sliding /pop-up roof (M12) cannot recognize the position of the roof.
In this case control is possible only to a limited extent; it is only possible to open the pop-up roof for synchronization.
Synchronizing
When the sliding /pop-up roof (M12) is moved to the mechanical end position "pop-up roof open" in the desynchronized state, the evaluation electronic module recognizes that the motor is locked up and then performs synchronization ; the position counter is set to "0" and the sliding /pop-up roof can then be operated again without limitations.
| Closing sliding /pop-up roof, function | GF77.20-P-2002GH | ||
| Desynchronizing sliding /pop-up roof, function | GF77.20-P-3003GH | ||
| Sliding/pop-up roof, location/purpose/ design/ function | GF77.20-P-4100GH | ||
| Sliding /pop-up roof lock-up recognition, function | GF77.20-P-3000GH | ||
| Sliding / pop-up roof position measurement, function | GF77.20-P-3001GH |