Closing sliding /pop-up roof, function - GF77.20-P-2002GH
MODEL 163 with CODE (414a) Electric glass sliding/pop-up roof
Function prerequisites
- Voltage not too low or too high
- Switch-on conditions for convenience control fulfilled
Function
The sliding roof and pop-up roof can be closed by pressing the switch (SR, S13/2) . The sliding/pop-up roof can only be closed by continuously pressing the switch (SR, S13/2) .
The express close function is not available for safety reasons.
If the sliding/pop-up roof has not been synchronized, it opens only in the pop-up roof direction each time the switch (SR, S13/2) is actuated. Upon reaching its end position, i.e. before the pop-up roof is completely open, synchronization is accomplished.
After successful synchronization, the sliding/pop-up roof can then be controlled without limitations.
Vehicles up to 11.99:
The power for the sliding/pop-up roof (M12) is supplied via a fuse directly to c. 30.
The power for the switch (SR, S13/2) is supplied via the convenience relay (F1k14) , which is actuated by the all-activity module (AAM, N10)
Vehicles as of 12.99:
The power for the sliding/pop-up roof (M12) is supplied via a fuse directly to c. 30. The power for the switch (SHD, S13/2) is supplied via a lead to the extended-activity module (EAM, N10/1) , this power is switched through only when the switch-on conditions for the convenience control are fulfilled and the EAM is coded accordingly.
| Opening pop-up roof, function | GF77.20-P-2003GH | ||
| Opening sliding roof, function | GF77.20-P-2004GH | ||
| Synchronizing sliding /pop-up roof, function | GF77.20-P-3002GH | ||
| Sliding/pop-up roof, location/purpose/ design/ function | GF77.20-P-4100GH | ||
| Convenience control | GF72.29-P-2002GH | ||
| All-activity module (AAM) | up to 11.99 | GF54.21-P-4100GH | |
| Extended-activity module, location/ purpose/ design | as of 12.99 | GF54.21-P-4107GK |