Convenience closing of power windows function - GF72.29-P-3005A
MODELS 202 as of 1.6.97, 208, 210.081 /281 (except 208.4), 210 (except 210.081 /281) as of 1.3.97
Function prerequisites
- No overvoltage/undervoltage
- circuit 15 off and
- circuit 15R off and
- circuit 15c off detected
Function
Each door control module (N69/1) or (N69/2), (MODELS 202/210 also N69/3 or N69/4) receives over CAN the request for convenience closing and then actuates the power window motor .
The motor is actuated until the door control module detects through position recognition that the window is closed.
When operating using the transmitter key
or lock switch
(
,
) the convenience closing function of the power window is also performed for non-normalized windows.
The convenience closing function is aborted if
- the request over CAN is no longer received or
- lock-up of the power window is detected or
- the function requirements listed above are no longer satisfied.
| Position recognition for power windows | GF72.29-P-4000A | ||
| Lock up recognition for power windows | GF72.29-P-4001A | ||
| Synchronization of power windows | GF72.29-P-4003A | ||
| Convenience opening of the power windows | GF72.29-P-3004A | ||
| Convenience actuation using transmitter key | GF80.45-P-2003A | ||
| Convenience actuation using lock switch | GF80.45-P-2004A |