TELE AID, diagnosis, functional check - AD82.95-P-3000A
MODELS 129, 202, 208.3, 210 as of 1.6.98 with CODE (347) TELE AID emergency call system (D2B)
MODELS 140, 210 up to 31.5.98 with CODE (348) TELE AID emergency call system
| TELE AID, diagnosis, previous knowledge | AD82.95-P-2000A | ||
| TELE AID, location of components | Model 129 as of 1.6.98 with CODE (347) TELE AID emergency call system (D2B) | GF82.95-P-0001-01E | |
| Model 140 except 140.063/07 with CODE (348) TELE AID emergency call system with CODE (930) taxi emergency call | GF82.95-P-0001-01A | ||
| Model 202 as of 1.6.98 up to 31.5.00 with CODE (347) TELE AID emergency call system (D2B) with CODE (930) taxi emergency call Model 208.3 as of 1.6.98 up to 31.5.00 with CODE (347) TELE AID emergency call system (D2B) |
GF82.95-P-0001-01F | ||
| Model 210 except 210.2 as of 1.6.98 with CODE (347) TELE AID emergency call system (D2B) Model 210 except 210.2 up to 31.5.98 with CODE (348) TELE AID emergency call system Model 210 except 210.2 with CODE (930) taxi emergency call |
GF82.95-P-0001-01B | ||
| Models 140.063/07 with CODE (348) TELE AID emergency call system | GF82.95-P-0001-01C | ||
| Model 210.2 as of 1.6.98 with CODE (347) TELE AID emergency call system (D2B) Model 210.2 up to 31.5.98 with CODE (348) TELE AID emergency call system Model 210.2 with CODE (930) taxi emergency call |
GF82.95-P-0001-01D | ||
| Model 210 with CODE (855) TELE AID with CODE (930) taxi emergency call | GF82.95-P-0001-01DA | ||
| Connect hand-held tester (HHT), read out fault memory | AD00.00-P-2000-03A | ||
| Function check | |||
| Scope of test | Operation / Requirement | Specified value | Possible cause / Remedy |
| 1 TELE AID activation behavior |
Turn ignition switch (S2) to position 1 (terminal 15R) | The "SOS" malfunction indicator lamp in the TELE AID emergency call system pushbutton switch (S93/3) must illuminate for approx. 4 s and subsequently extinguish. | AD82.95-P-5000A |
| 2 TELE AID emergency call system (S93/3) pushbutton switch illumination |
Switch exterior lamp switch (S1) on (terminal 58d: ON) | TELE AID emergency call system pushbutton switch (S93/3) is illuminated by the integrated "SOS" LED. | AD82.95-P-6000-13A |
| 3 Telephone |
Terminal 15R: ON Switch telephone on at the telephone handset (A34). If necessary: Input PIN number. |
The display on the telephone handset (A34) is activated. The telephone system is operational. The telephone system is controlled by TELE AID. If a telephone overshoot time has been set on the handset (A34), the telephone is still operational after terminal 15R has been switched off (for the duration of the overshoot time which has been set). | AD82.95-P-6000-08A |