Xenon headlamps (XENON) diagnosis, troubleshooting - AD82.10-P-5001A
MODEL 202, 208, 210 with CODE (612) Xenon headlamp unit
| Risk of death
caused by high voltage levels present at xenon headlamps. Risk of explosion/risk of fire due to highly flammable materials in the area of damaged xenon bulbs Risk of injury from UV light, hot components at xenon headlamps and glass splinters when xenon bulbs crack Risk of poisoning from inhaling mercury vapors and from swallowing/skin contact with poisonous salts and mercury compounds |
Do not come into contact with parts that are under high voltage. Persons with active electronic implants (e.g. heart pacemakers) must never work on xenon headlamps. Switch off entire lighting system. Wear insulating safety shoes, safety glasses and protective gloves. Remove highly inflammable materials from the hazard area. Ensure the work area is adequately ventilated. | AS82.10-Z-0001-01A | |
| Xenon headlamps (XENON) Diagnosis, basic knowledge | AD82.10-P-2001A | ||
| Xenon headlamp (XENON), location of components | Model 208, 210 | GF82.10-P-0002-01A | |
| Model 202 | GF82.10-P-0002-01B | ||
| Low beam: ON | |||
| Troubleshooting | |||
| Complaint | Possible cause | Note | Remedy |
| Xenon headlamp low beam (E1e8 and E2e8) on left and right nonfunctional |
|
Model 208, 210: ↓ AD82.10-P-6001A Model 202: ↓ AD82.10-P-6001B |
|
| Xenon headlamp low beam (E1e8) on left nonfunctional |
|
To protect against consequential damage before replacing the xenon bulbs (D2R, 35W) always determine the output | Model 208, 210: ↓ AD82.10-P-6001-01A Model 202: ↓ AD82.10-P-6001-01B |
| Xenon headlamp low beam (E2e8) on right nonfunctional |
|
To protect against consequential damage before replacing the xenon bulbs (D2R, 35W) always determine the output | Model 208, 210 right hand drive: ↓ AD82.10-P-6001-02B Model 202: ↓ AD82.10-P-6001-02C |