Instrument Cluster Configuration
WARNING: This page is about a different car, the 2009 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
- Use the IDS (laptop PC) because the PDS (Pocket PC) does not support the INSTRUMENT CLUSTER CONFIGURATION.
NOTE:
- If all the following conditions are met, the odometer data (total traveled distance) in the previous instrument cluster is automatically transferred to a new instrument cluster during the configuration. If any of the conditions are not met, odometer-data transfer cannot be performed.
Previous Instrument cluster
- No malfunction (Configuration data can be read using the M-MDS.
New Instrument cluster
- Odometer display is less than 100 km
- Odometer has no malfunction
- Connect the M-MDS to the DLC-2.
- After the vehicle is identified, select the following items from the initial screen of the M-MDS.
- Select the "Module Programming".
- Then, select items from the screen menu in the following order.
- Select "Programmable Module Installation".
- Select "IC".
- Perform the configuration according to the directions on the screen.
- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
- Select "Programmable Parameters" from the menu.
- Select "Odometer Write", and perform the procedure following the screen.
- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
- Retrieve DTCs by the M-MDS, then verify that there is no DTC present.
- If a DTC (s) is detected, perform the applicable DTC inspection. See DTC TABLE [INSTRUMENT CLUSTER] .