Home >> Lexus >> 2017 >> IS 300 F Sport >> Repair and Diagnosis >> External Pages >> Different car >> Section 83 (Automatic Transmission System (A760H) - Diagnostic Codes (2 Of 3)) >> AUTOMATIC TRANSMISSION SYSTEM (for 2GR-FKS) >> DTC P0755-15: Shift Solenoid "B" Circuit Short to Battery or Open [10/2017 - ] >> Procedure

DTC P0755-15: Shift Solenoid "B" Circuit Short to Battery or Open [10/2017 - ]: Procedure

WARNING: This page does not describe the selected car, but rather 14 other vehicles, including the 2024 Lexus IS 350, 2024 Lexus IS 300, 2023 Lexus IS 350, 2023 Lexus IS 300, and 2022 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2) 
    1. Disconnect the F56 transmission wire connector.
      GTY468211Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Component without harness connected
      (Transmission Wire)
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      15 (S2) - Body ground 20°C (68°F) 11 to 15 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    See step  3

    Result: 

    OK 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) 
    1. Disconnect the F102 ECM connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      F102-77 (S2) - Body ground 20°C (68°F) 11 to 15 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE ECM. Refer to  COMPONENTS [10/2017 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

  3. INSPECT SHIFT SOLENOID VALVE S2 
    1. Remove the shift solenoid valve S2.
      GTY629711Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *1 Shift Solenoid Valve S2

      Refer to DISASSEMBLY [04/2013 - ]

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      Terminal of shift solenoid valve S2 connector - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω
    3. Connect a positive (+) lead from the battery to the terminal of the shift solenoid valve connector, and a negative (-) lead to the shift solenoid valve body. Check that the valve moves and makes an operating sound.

      OK

      Valve moves and makes an operating sound.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPAIR OR REPLACE TRANSMISSION WIRE. Refer to  COMPONENTS [04/2013 - ] 

    Result: 

    NG 

    REPLACE SHIFT SOLENOID VALVE S2. Refer to  COMPONENTS [04/2013 - ]