Inspection Procedure
- INSPECT FUSE (LH-IG)
- Remove the LH-IG fuse from the cowl side junction block LH.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONSTester Item Condition Specified Condition LH-IG fuse Always Below 1 Ω
NG: REPLACE FUSE (LH-IG)
OK: Go to next step
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor
- Select the item below in the Data List, and read the display on the Techstream.
Data List / Air Conditioner
DATA LIST / AIR CONDITIONERTester Display Measurement Item/Range Normal Condition Diagnostic Note Emission Gas Sensor (Emiss Gas Sens) Emission gas / Min 0, Max 255 Smog ventilation sensor value increases as gas amount increases - OK: The display is as specified in the normal condition column.
Result
RESULT DESCRIPTIONResult Proceed to NG A OK (When troubleshooting according to the Problem Symptoms Table) B OK (When troubleshooting according to the DTC) C
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (See PROBLEM SYMPTOMS TABLE )
C: REPLACE A/C AMPLIFIER (See REMOVAL )
A: Go to next step
- CHECK HARNESS AND CONNECTOR (SMOG VENTILATION SENSOR - BODY GROUND)
- Disconnect the smog ventilation sensor connector.
- Measure the resistance according to the value(s) in the table below
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONSTester Connection Condition Specified Condition B11-6 (E) - Body ground Always Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SMOG VENTILATION SENSOR - BATTERY)
- Measure the voltage according to the value(s) in the table below
Standard Voltage
STANDARD VOLTAGE SPECIFICATIONSTester Connection Condition Specified Condition B11-3 (IG) - Body ground Engine switch on (IG) 11 to 14 V Engine switch off Below 1 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- Measure the voltage according to the value(s) in the table below
- INSPECT SMOG VENTILATION SENSOR
- Remove the smog ventilation sensor
- Connect a battery positive (+) lead to terminal 3 (IG) and negative (-) lead to terminal 6 (E)
- Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor, and measure the resistance between terminals 1 (SG) and 2 (DGS)
OK: When the sensor is exposed to the exhaust gas, the resistance increases.
HINT:
The resistance before blowing exhaust gas is 10 kΩ to 40 kΩ.
NG: REPLACE SMOG VENTILATION SENSOR (See REMOVAL )
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SMOG VENTILATION SENSOR - A/C AMPLIFIER)
- Disconnect the A/C amplifier connector
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONSTester Connection Condition Specified Condition B11-1 (SG) - J58-39 (SG-6) Always Below 1 Ω B11-2 (DGS) - J58-34 (DGS) Always Below 1 Ω J58-39 (SG-6) - Body ground Always 10 kΩ or higher J58-34 (DGS) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE A/C AMPLIFIER (See REMOVAL )