Alternative Procedure
WARNING: This page is about a different variant/trim than selected.
NOTE:
If the electric fuel pump is not operating, the fuel tank must be removed and drained through the fuel pump module opening of the fuel tank.
- Perform the Fuel System Pressure Release procedure. Refer to FUEL SYSTEM PRESSURE RELEASE .
- Disconnect and isolate the negative battery cable(s). Refer to BATTERY DISCONNECT AND CONNECT .
- Raise and support the vehicle. Refer to HOISTING, STANDARD PROCEDURE .
- Remove the fuel tank. Refer to TANK, FUEL, REMOVAL AND INSTALLATION .
- Remove the fuel pump module. Refer to MODULE, FUEL PUMP, REMOVAL AND INSTALLATION .
- Position a 3/8" hose into the fuel pump module opening of the fuel tank.
- Attach the opposite end of this hose to the Fuel Chief Gas Caddy 320-FC-P30-A or an OSHA approved gas caddy.
- Using the gas caddy, evacuate the fuel tank.