Rear Blower Motor 1
- CHECK FUSE
Check 20A fuse [No. 70, located in the fuse block (J/B)].
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Replace the blown fuse after repairing the affected circuit.
- CHECK POWER SUPPLY FOR REAR BLOWER MOTOR 1
- Turn ignition switch ON.
- Check voltage between rear blower motor 1 harness connector and ground.
(+) (-) Voltage
(Approx.)Rear blower motor 1 Connector Terminal M107 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 7 .
- CHECK POWER SUPPLY FOR REAR BLOWER MOTOR RESISTOR 1
Check voltage between rear blower motor resistor 1 harness connector and ground.
(+) (-) Voltage
(Approx.)Rear blower motor resistor 1 Connector Terminal M104 1 Ground Battery voltage Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 8 .
- CHECK BLOWER MOTOR CONTROL SIGNAL
- Turn mode control to VENT.
- Turn fan control to 1st speed.
- Check voltage between rear blower motor resistor 1 harness connector and ground.
(+) (-) Voltage
(Approx.)Rear blower motor resistor 1 Connector Terminal M104 2 Ground 2.5 V
Is the inspection result normal?
YES
GO TO STEP 5 .
NO - 1
Less than approximately 2.5 V: GO TO STEP 9 .
NO - 2
More than approximately 10 V: Replace auto amp.
- CHECK REAR BLOWER MOTOR RESISTOR 1 GROUND CIRCUIT
- Disconnect rear blower motor resistor 1 connector.
- Check continuity between rear blower motor resistor 1 harness connector and ground.
Rear blower motor resistor 1 - Continuity Connector Terminal M104 3 Ground Yes
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair harness or connector.
- CHECK BLOWER MOTOR FEEDBACK SIGNAL
- Reconnect rear blower motor resistor 1 connector.
- Turn ignition switch ON.
- Turn fan control to 1st speed.
- Check voltage between auto amp. harness connector and ground.
(+) (-) Condition Voltage
(Approx.)Auto amp. Connector Terminal M50 34 Ground Blower speed: 1st
(Blower motor operating)10 V
Is the inspection result normal?
YES
Replace auto amp.
NO
Repair harness or connector.
- CHECK POWER SUPPLY OF REAR BLOWER MOTOR RELAY
- Turn ignition switch OFF.
- Remove blower relay.
- Turn ignition switch ON.
- Check voltage between rear blower motor relay connector terminals and ground.
(+) (-) Voltage
(Approx.)
Rear blower motor relayConnector Terminal M108 1 Ground Battery voltage 3 6
Is the inspection result normal
YES
Check rear blower motor relay . Refer to COMPONENT INSPECTION (REAR BLOWER MOTOR RELAY) .
NO
Repair harness or connector .
- CHECK CIRCUIT CONTINUITY BETWEEN BLOWER MOTOR AND REAR BLOWER MOTOR RESISTOR 1
- Turn ignition switch OFF.
- Disconnect rear blower motor resistor 1 connector.
- Check continuity between rear blower motor 1 harness connector and rear blower motor resistor 1 harness connector.
Rear blower motor 1 Rear blower motor resistor 1 Continuity Connector Terminal Connector Terminal M107 2 M104 1 Yes
Is the inspection result normal?
YES
Replace rear blower motor 1.
NO
Repair harness or connector.
- CHECK REAR BLOWER MOTOR RESISTOR 1
Check rear blower motor resistor 1 Refer to COMPONENT INSPECTION (REAR BLOWER MOTOR RESISTOR) .
Is the inspection result normal?
YES
Replace auto amp.
NO
Replace rear blower motor resistor 1.