Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM - WITH AUTOMATIC DRIVE POSITIONER or WIRING DIAGRAM - WITHOUT AUTOMATIC DRIVE POSITIONER .
- CHECK FUSES
Check for blown combination meter fuses.
Unit Power source Fuse No. Combination meter Battery 13 65 Ignition switch ON or START 31 Is the inspection result normal?
YES
GO TO STEP 2
NO
Replace the fuse after repairing the affected circuit.
- POWER SUPPLY CIRCUIT CHECK
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector M24 terminals 5, 21, 22 and ground.
Terminals Ignition switch position (+) (-) OFF ACC ON START Connector Terminal M24 22 Ground Battery voltage Battery voltage Battery voltage Battery voltage 21 0V 0V Battery voltage Battery voltage 5 0V Battery voltage Battery voltage 0V Is the inspection result normal?
YES
GO TO STEP 3
NO
Repair or replace harness or connectors.
- GROUND CIRCUIT CHECK
- Turn ignition switch OFF.
- Check continuity between combination meter harness connector M24 terminals 1, 2 and ground.
Terminals Continuity (+) (-) Connector Terminal M24 1 Ground Yes 2 Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connectors.