Diagnosis Procedure
- CHECK BCM INPUT SIGNAL
- Connect the CONSULT.
- Check the BCM input signals. Refer to
"COMPONENT FUNCTION CHECK
".
Is the inspection result normal?
YES: GO TO 2.
NO: GO TO 3.
- CHECK COMBINATION METER INPUT SIGNAL
Select the "Data Monitor" for the "METER/M&A" and check the "TRUNK/GLAS-H" monitor value.
"TRUNK/GLAS-H"
Trunk lid open: On
Trunk lid closed: Off
Is the inspection result normal?
YES: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".
NO: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- CHECK TRUNK LID OPEN SIGNAL CIRCUIT
Check trunk lid open signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 4.
NO: Repair harness or connector.
- CHECK TRUNK CLOSURE ASSEMBLY
Check trunk closure assembly. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".
NO: Replace trunk closure assembly. Refer to "REMOVAL AND INSTALLATION "