Diagnosis Procedure
- INSPECTION START
Check that which circuit is malfunctioning. Refer to "COMPONENT FUNCTION CHECK ".
Which circuit is malfunctioning?
Output signal circuit: GO TO 2.
Input signal circuit: GO TO 4.
- CHECK TRUNK LID OPEN REQUEST SIGNAL
- Turn ignition switch ON.
- Select "TRUNK/BACK DOOR" in "Active Test" mode of "INTELLIGENT KEY" of "BCM" using CONSULT.
- Check voltage between trunk closure assembly harness connector and ground when touching "OPEN".
(+) (-) CONSULT Active Test condition Voltage (V) (Approx.) Trunk closure assembly Connector Terminal T14 1 Ground TRUNK/GLASS HATCH OPEN 0 → 12 → 0 Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 3.
- CHECK TRUNK LID OPEN REQUEST SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect negative battery cable.
- Disconnect BCM connector.
- Disconnect trunk closure assembly harness connector.
- Check continuity between BCM harness connector and trunk closure assembly harness connector.
BCM Trunk closure assembly Continuity Connector Terminal Connector Terminal M121 53 T14 1 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M121 53 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair harness or connector.
- CHECK TRUNK LID OPEN/CLOSE STATUS SIGNAL
- Check voltage between BCM harness connector and ground under the following conditions.
(+) (-) Condition Voltage (V) (Approx.) BCM Connector Terminal M121 42 Ground Trunk lid Open 0 Closed 12 Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- Check voltage between BCM harness connector and ground under the following conditions.
- CHECK TRUNK LID OPEN/CLOSE STATUS SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect negative battery cable.
- Disconnect BCM connector.
- Disconnect trunk closure assembly harness connector.
- Check continuity between BCM harness connector and trunk closure assembly harness connector.
BCM Trunk closure assembly Continuity Connector Terminal Connector Terminal M121 42 T14 5 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M121 42 Not existed Is the inspection result normal?
YES: Replace trunk closure assembly. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair harness or connector.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END