LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2022 >> Transit Connect Titanium, Gas/Ethanol >> Repair and Diagnosis >> Body & Frame >> Windows >> Glass, Frames And Mechanisms >> Diagnosis And Testing >> Glass, Frames and Mechanisms - Vehicles With: One-Touch Open Driver Window >> Pinpoint Test(s) >> Pinpoint Test E: A Single Power Window Is Inoperative - RH (Right-Hand) Front

Pinpoint Test E: A Single Power Window Is Inoperative - RH (Right-Hand) Front

  1. Refer to POWER WINDOWS for schematic and connector information.

    Normal Operation and Fault Conditions 

    REFER to: Glass, Frames and Mechanisms - Vehicles With: One-Touch Open Driver Window - System Operation and Component Description .

    Possible Sources 

    • Wiring, terminals or connectors
    • Master window control switch
    • RH front window control switch
    • RH front window regulator motor

  2. E1 CHECK THE RH WINDOW CONTROL SWITCH POWER CIRCUIT FOR AN OPEN

    • Ignition OFF.

    • Disconnect: RH Front Window Control Switch C643.

    • Ignition ON.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C643-2
      GFD574097Courtesy of FORD MOTOR COMPANY
      Ground

    Is the voltage greater than 11 volts? 

    Yes  GO to  E2
    No  REPAIR the circuit.
  3. E2 CHECK THE MASTER WINDOW CONTROL SWITCH NORMALLY CLOSED GROUND CIRCUITS FOR AN OPEN

    • Ignition OFF.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C643-3
      GFD574098Courtesy of FORD MOTOR COMPANY
      Ground
      C643-6
      GFD574098Courtesy of FORD MOTOR COMPANY
      Ground

    Are the resistances less than 3 ohms? 

    Yes  GO to  E4
    No  GO to  E3
  4. E3 CHECK THE POWER WINDOW CONTROL CIRCUITS FOR AN OPEN

    • Disconnect: Master Window Control Switch C504B.

    • If equipped with power rear windows, measure:
      Positive Lead Measurement / Action Negative Lead
      C504B-7
      GFD574098Courtesy of FORD MOTOR COMPANY
      C643-6
      C504B-8
      GFD574098Courtesy of FORD MOTOR COMPANY
      C643-3

    Are the resistances less than 3 ohms? 

    Yes  INSTALL a new master window control switch. REFER to: Front Door Window Control Switch .
    No  REPAIR the circuit in question.
  5. E4 CHECK THE POWER WINDOW UPWARD AND/OR DOWNWARD OPERATION

    • Ignition ON.

    • To check downward window operation, connect fused jumper wires:
      Positive Lead Measurement / Action Negative Lead
      C643-2
      GFD574099Courtesy of FORD MOTOR COMPANY
      C643-7
      C643-6
      GFD574099Courtesy of FORD MOTOR COMPANY
      C643-1

    • To check upward window operation, connect fused jumper wires:
      Positive Lead Measurement / Action Negative Lead
      C643-2
      GFD574099Courtesy of FORD MOTOR COMPANY
      C643-1
      C643-6
      GFD574099Courtesy of FORD MOTOR COMPANY
      C643-7

    Does the RH front window move up and/or down? 

    Yes  REMOVE the jumper wires. If the RH front window did not operate from the RH front window control switch, INSTALL a new RH window control switch. REFER to: Front Door Window Control Switch . If the RH front window did not operate from the master window control switch, INSTALL a new master window control switch. REFER to: Front Door Window Control Switch .
    No  REMOVE the jumper wires. GO to  E5
  6. E5 CHECK THE POWER WINDOW CIRCUITS FOR AN OPEN

    • Ignition OFF.

    • Disconnect: RH Front Power Window Motor C608.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C643-1
      GFD574098Courtesy of FORD MOTOR COMPANY
      C608-2
      C643-7
      GFD574098Courtesy of FORD MOTOR COMPANY
      C608-1

    Are the resistances less than 3 ohms? 

    Yes  MAKE SURE there are no mechanical binding conditions preventing the glass mechanism from operating correctly. If a mechanical binding issue is found, REPAIR as necessary. If no mechanical binding condition exists, INSTALL a new RH front window regulator motor. REFER to: Front Door Window Regulator Motor .
    No  REPAIR the circuit in question.