LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2018 >> Taurus Limited, FWD, Gas >> Repair and Diagnosis >> External Pages >> Different car >> Section 115 (Climate Control System - General Information (1 Of 2)) >> Diagnosis And Testing >> Climate Control System - Vehicles With: Electronic Manual Temperature Control (EMTC) >> Pinpoint Test(s) >> Pinpoint Test J : The Blower Motor Is Inoperative

Pinpoint Test J : The Blower Motor Is Inoperative

WARNING: This page is about a different car, the 2018 Ford EcoSport. However, it is still accessible from the selected car via links, so may be relevant.
  1. Refer to MANUAL CLIMATE CONTROL SYSTEM for schematic and connector information.

    Normal Operation and Fault Conditions 

    Air Handling, REFER to: Climate Control System - Vehicles With: Electronic Automatic Temperature Control (EATC) - System Operation and Component Description .

    DTC Fault Trigger Conditions 

    DTC Description Fault Trigger Condition
    HVAC B10AF:11 Blower Fan Relay: Circuit Short To Ground This DTC sets when the HVAC control module senses no voltage change on the blower motor relay coil control circuit when the module attempts to engage the relay, indicating a short directly to ground. The blower motor is inoperative.
    HVAC B10AF:15 Blower Fan Relay: Circuit Short To Battery Or Open This DTC sets when the HVAC control module senses no ground on the blower motor relay coil control circuit when the module attempts to engage the relay, indicating an open circuit or a short directly to voltage. The blower motor is inoperative when the relay control circuit is open. The blower motor is always on when the relay control circuit is shorted to voltage.
    HVAC B10B9:12 Blower Control: Circuit Short To Battery This DTC sets when the HVAC control module senses excessive voltage on the blower motor speed control PWM circuit, indicating a short directly to voltage. The blower motor is inoperative.
    HVAC B10B9:14 Blower Control: Circuit Short To Ground Or Open This DTC sets when the HVAC control module senses no voltage on the blower motor speed control PWM circuit, indicating an open or a short directly to ground. The blower motor is inoperative.

    Possible Sources 

    • Wiring, terminals or connectors
    • Blower motor relay
    • Blower motor
    • Blower motor speed control
    • HVAC control module

    Visual Inspection and Pre-checks 

    • Inspect BJB fuse 6 (40A).

  2. NOTE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
  3. J1 CHECK THE BLOWER MOTOR RELAY FUNCTIONALITY

    • Ignition OFF.

    • Disconnect Blower motor relay.

    Did the relay pass the component test? 

    Yes  GO to  J2
    No  INSTALL a new blower motor relay.
  4. J2 CHECK THE BLOWER MOTOR RELAY COIL GROUND CIRCUIT FOR AN OPEN

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Blower motor relay socket 2 (component side)
      GFD328095Courtesy of FORD MOTOR COMPANY
      Ground

    Is the resistance less than 3 ohms? 

    Yes  GO to  J3
    No  REPAIR the circuit.
  5. J3 CHECK THE BLOWER MOTOR RELAY SWITCH CONTACT SUPPLY VOLTAGE

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Blower motor relay socket 3 (component side)
      GFD328094Courtesy of FORD MOTOR COMPANY
      Ground

    Is the voltage greater than 11 volts? 

    Yes  GO to  J4
    No  VERIFY BJB fuse 6 (40A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the OEM ELECTRICAL WIRING DIAGRAM INTRODUCTION to identify the possible causes of the circuit short.
  6. J4 CHECK THE BLOWER MOTOR RELAY COIL CONTROL CIRCUIT FOR A SHORT TO GROUND

    • Disconnect HVAC control module C2357A.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Blower motor relay socket 1 (component side)
      GFD328095Courtesy of FORD MOTOR COMPANY
      Ground

    Is the resistance greater than 10, 000 ohms? 

    Yes  GO to  J5
    No  REPAIR the circuit.
  7. J5 CHECK THE BLOWER MOTOR RELAY COIL CONTROL CIRCUIT FOR AN OPEN

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Blower motor relay socket 1 (component side)
      GFD328095Courtesy of FORD MOTOR COMPANY
      C2357A-11

    Is the resistance less than 3 ohms? 

    Yes  GO to  J6
    No  REPAIR the circuit.
  8. J6 CHECK THE BLOWER MOTOR SPEED CONTROL VOLTAGE CIRCUIT FOR AN OPEN

    • Disconnect Blower motor speed control C297A.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Blower motor relay socket 5 (component side)
      GFD328095Courtesy of FORD MOTOR COMPANY
      C297A-4

    Is the resistance less than 3 ohms? 

    Yes  GO to  J7
    No  REPAIR the circuit.
  9. J7 CHECK THE BLOWER MOTOR SPEED CONTROL GROUND CIRCUIT FOR AN OPEN

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C297A-2
      GFD328095Courtesy of FORD MOTOR COMPANY
      Ground

    Is the resistance less than 3 ohms? 

    Yes  GO to  J8
    No  REPAIR the circuit.
  10. J8 CHECK THE BLOWER MOTOR SPEED CONTROL PWM (PULSE WIDTH MODULATION) CIRCUIT FOR A SHORT TO VOLTAGE

    • Ignition ON.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C297A-3
      GFD328094Courtesy of FORD MOTOR COMPANY
      Ground

    Is any voltage present? 

    Yes  REPAIR the circuit.
    No  GO to  J9
  11. J9 CHECK THE BLOWER MOTOR SPEED CONTROL PWM (PULSE WIDTH MODULATION) CIRCUIT FOR A SHORT TO GROUND

    • Ignition OFF.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C297A-3
      GFD328095Courtesy of FORD MOTOR COMPANY
      Ground

    Is the resistance greater than 10, 000 ohms? 

    Yes  GO to  J10
    No  REPAIR the circuit.
  12. J10 CHECK THE BLOWER MOTOR SPEED CONTROL PWM (PULSE WIDTH MODULATION) CIRCUIT FOR AN OPEN

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C297A-3
      GFD328095Courtesy of FORD MOTOR COMPANY
      C2357A-23

    Is the resistance less than 3 ohms? 

    Yes  GO to  J11
    No  REPAIR the circuit.
  13. J11 CHECK THE OUTPUTS TO THE BLOWER MOTOR

    • Disconnect Blower motor C2004.

    • Connect Blower motor relay.

    • Connect Blower motor speed control C297A.

    • Connect HVAC control module C2357A.

    • Ignition ON.

    • Select PANEL on the HVAC controls.

    • Select the highest blower motor setting.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C2004-1
      GFD328094Courtesy of FORD MOTOR COMPANY
      C2004-2

    Is the voltage greater than 11 volts? 

    Yes  INSTALL a new blower motor. REFER to: Blower Motor .
    No  GO to  J12
  14. J12 CHECK THE CIRCUITS TO THE BLOWER MOTOR FOR AN OPEN

    • Ignition OFF.

    • Disconnect Blower motor speed control C297B.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C297B-1
      GFD328095Courtesy of FORD MOTOR COMPANY
      C2004-1
      C297B-2
      GFD328095Courtesy of FORD MOTOR COMPANY
      C2004-2

    Are the resistances less than 3 ohms? 

    Yes  GO to  J13
    No  REPAIR the circuit in question.
  15. J13 CHECK THE BLOWER MOTOR CIRCUITS FOR A SHORT TOGETHER

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C297B-1
      GFD328095Courtesy of FORD MOTOR COMPANY
      C297B-2

    Is the resistance greater than 10, 000 ohms? 

    Yes  INSTALL a new blower motor speed control. REFER to: Blower Motor Speed Control . TEST the system for normal operation. If the concern is still present, GO to  J14
    No  REPAIR the circuits.
  16. J14 CHECK FOR CORRECT HVAC (HEATING, VENTILATION AND AIR CONDITIONING) CONTROL MODULE OPERATION

    • Ignition OFF.

    • Disconnect and inspect all HVAC control module electrical connectors (if not previously disconnected).

    • Repair:

      • corrosion (install new connector or terminal - clean module pins)
      • damaged or bent pins - install new terminals or pins
      • pushed-out pins - install new pins as necessary

    • Connect all HVAC control module electrical connectors. Make sure they seat and latch correctly.

    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new HVAC control module. REFER to: Heating, Ventilation and Air Conditioning (HVAC) Control Module .
    No  The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.